Search results for “sample pan for dsc testing”
Products
65μl Alumina Crucible for Hitachi(Seiko)GAA-1980 and K-YSSC520B005 Al2O3 Pan | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Hitachi(Seiko),Bruker AXS Part NO A-H-2 same design as Hitachi(Seiko)GAA-1980 and K-YSSC5...
View full details0.15ml Alumina Crucibles Netzsch GB399147 for Netzsch | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Netzsch STA 449 F1/F3 Jupiter and DSC 404 F1/F3 Pegasus Part NO A-NE-19 same design as Netzsch GB399...
View full detailsPlatinum Lid for 40μl/110μl Sample Cup for TA Instruments DSC Accessories | NEXACULE
NEXACULEType Sample pan /crucible cover Suitable for TA TGA Q5000 Part NO A-TA-38 PT lid suit for TA PT crucible 957207.904 ;960148.901 ...
View full detailsOEM 85μl Alumina Ceramic Crucibles Only for Mettler Toledo/Mettler Al2O3 Sample Pans Al2O3 Crucible | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Mettler TGA/sample robot Size D6.5*5*0.5mm With R arc Part No. A-M-07 Volume μL 85 μL Lid ...
View full details150μl Alumina Large Crucibles with Lid for ME-00024124 for Mettler Toledo/Mettler Al2O3 Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Mettler ME/sample robot Part NO A-M-09 same design as ME-00024124 Volume 150 μL Lid...
View full detailsPlatinum Crucible Tongs SS Crucible Tong Lab Equipment | NEXACULE
NEXACULEPlatinum-Tip Crucible Tongs - Professional Laboratory Equipment Product Overview Our premium platinum-tip crucible tongs represent the highest stan...
View full details70μl Alumina Crucibles Medium with Lids for ME-00024123 for Mettler Toledo/Mettler Al2O3 Sample Pans | NEXACULE
NEXACULEItem Sample pan /crucible with lid Suitable for Mettler TGA/sample robot Part NO A-M-06 same design as ME-00024123 Volume 70μL Lid W...
View full detailsAlumina Crucibles Size D5*4mm for Hitachi(Seiko) Aluminum Ceramic Crucible | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Hitachi(Seiko),Bruker AXS Part NO A-EA-159-1 Volume μL Size 5*4mm Lid Withou...
View full details30μl Platinum Crucible Small With Lid for ME-51140842 for Mettler Toledo/Mettler PT Sample Pans | NEXACULE
NEXACULEType PT Crucible for DSC/TGA/sample robot Suitable for A-M-32 same design as Mettler ME-51140842 Size 30ul Material Platinum Matc...
View full detailsPlatinum Sample Hang-Down Wire for TA 952040.901 for TA Instruments/TA DSC Accessories | NEXACULE
NEXACULEType Platinum Wire Suitable for Hangdown Wire Q5000IR and Discovery TGA; Sample Wire for Q500/Q50 Part NO A-TA-42 Same Design As TA 952040...
View full detailsProtective Quartz for Sample Stage TA 944341.901 for TA Instruments/TA DSC Consumables | NEXACULE
NEXACULEType Protective Quartz Suitable for TA Instruments TMA 2940, Q400 & Q400E Part NO A-TA-15 equivalent to TA 944341.901 Sto...
View full detailsPDS Sample Plate/PDS Sample Sheet for Hitachi GCA-0020 Thermal Analyzers Sample Lid | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Hitachi Seiko Part NO A-H-6 for Hitachi GCA-0020 Size / Lid Without Mate...
View full details600μl Alumina Large Crucibles with Lid for ME-30077260 for Mettler Toledo/Mettler Al2O3 Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Mettler E/sample robot Part No A-M-11 same design as ME-30077260 Volume μL 600μL Lid...
View full details
Save $0.00
Save $0.00
Standard Sample Carriers Type S(PtRh)for Netzsch HTP40000A69.010-00 | NEXACULE
Standard Sample Carriers Type S(PtRh)for Netzsch HTP40000A69.010-00 | NEXACULE
NEXACULEStandard Sample Carriers Type S (PtRh) for Netzsch STA 449 Series Product Overview Professional-grade sample carriers designed specifically for Net...
View full details100μl Aluminum Crucibles for ME-51119872 For Mettler Toledo/Mettler Thermal Analysis Crucibles | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Mettler DSC/TGA/sample robot Part NO A-M-23 same design as ME-51119872 Volume μL 100 μL Pin Witho...
View full details25μL Reusable High Pressure Capsules Stainless steel Gold Plated with Seal for TA Instruments/TA | NEXACULE
NEXACULEType High pressure capsules Suitable for TA DSC test Ambient to 300°C Pressure Range:1450 psig (10 MPa) Part No. A-TB-050-10 Lid With ...
View full detailsPlatinum Lids Size D5mm for PerKinElmer/PE Platinum Sample Pans Thermal Analysis Consumables | NEXACULE
NEXACULEType lid Suitable for PE Size D5mm Part No. A-PA-134-7 Temperature Range :-150~1600℃ Matching crucible Platinum/PT Crucible D5*H4m...
View full details5ml Alumina Ceramic Crucibles for NGB809163 for TGA Sample Carrier Of Netzsch Thermal Analysis Sample Pans | NEXACULE
NEXACULEType Alumina crucibles Suitable for Netzsch STA 449 F1/F3/F5 Jupiter®, STA 449 F3 Nevio Part No. A-NA-088-01 same design as Netzsch NGB8...
View full details40μl Platinum Sample Cup for TA 960148.901 for TA Instruments PT Crucible | NEXACULE
NEXACULEType Sample pan /crucible Suitable for TA SDT 2960 Q600 Part NO A-TA-39 Same Design As TA 960148.901 Capacity 40µL Mate...
View full detailsFilm/Fiber Probe Assembly TA 945051.901 for TA Instruments/TA DSC Accessories NEXACULE
NEXACULEType Film/Fiber Probe Suitable for TA Discovery TMA 450/450EM and Q400/Q400EM Part NO A-TM-033-5 Same Design As TA 945051.901 Material Qu...
View full details25μl Alumina Crucibles D7.5*2mm for Netzsch Ceramic Pans Thermal Analysis Consumables Al2O3 Pan | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Netzsch Part NO A-NE-2 Volume 25μl Size D7.5*2mm Lid Without Material Alumina Ceramic ...
View full details25μl Netzsch Alumina Crucibles D7*2mm for Netzsch Ceramic Pans DSC Consumables Al2O3 Pan | NEXACULE
NEXACULETypea Sample pan /crucible Suitable for Netzsch Part NO A-NE-1 Volume μL 25 μL Size D7*2MM Lid Without Material Alumina Ceramic...
View full details40μl Premium Alumina Sample Cup TA 960072.901 for TA Instruments/TA Thermal Analysis Crucible | NEXACULE
NEXACULEType Sample pan /crucible Suitable for TA SDT Q600/SDT 2960 Part NO A-TA-4 Same Design As TA 960072.901 Volume μL 40 μL Lid Withou...
View full detailsSample Holder Thermocouple for PE N5202083 for PerkinElmer/PE STA 6000 | NEXACULE
NEXACULEItem Thermocouple Suitable for PE N5202083 for PE STA 6000 Part NO A-PE-003 same design as PE N5202083 Stocking time 40 working days ...
View full details