Professional Compatible Hitachi (Seiko) Thermal Analysis Consumables
Building upon 30 years of expertise in thermal analysis, our comprehensive collection of Hitachi (Seiko) compatible consumables delivers exceptional performance for DSC, TGA, and simultaneous thermal analysis applications. Precision-engineered to match original equipment specifications, these high-quality replacement crucibles and sample pans ensure optimal analytical results while providing significant cost savings for research laboratories worldwide.
Our compatible Hitachi (Seiko) consumables maintain the same dimensional accuracy, thermal properties, and chemical resistance as original equipment, ensuring seamless integration with your existing analytical workflows. Each replacement component undergoes comprehensive quality testing to guarantee reliable performance across diverse analytical applications, from polymer characterization to pharmaceutical stability testing.
Advanced Features of Our Compatible Consumables:
- Precise Dimensional Matching: ±0.01mm tolerance ensures perfect instrument fit
- Equivalent Thermal Performance: Matched heat transfer characteristics for accurate measurements
- Superior Material Purity: High-grade aluminum, platinum, and ceramic construction
- Extended Temperature Range: Reliable operation from -170°C to 1600°C
- Cost-Effective Solutions: 40-60% savings compared to original equipment
- Comprehensive Testing: Each batch verified for dimensional accuracy and thermal stability
1. Thermogravimetric Analysis (TGA) Consumables
-
Crucibles & Sample Pan
- Alumina Crucibles: High-temperature resistance up to 2200°C, suitable for routine TGA experiments and high-temperature material analysis.
- Platinum Crucibles: For high-purity samples avoid contact with corrosive gases.
- Sealed Crucibles: Prevent mass loss of volatile or hygroscopic samples, ensuring accurate experimental results.
2. Differential Scanning Calorimetry (DSC) Consumables
-
Sensors & Accessories
- DSC Sensors: Nickel-chromium/constantan alloy, temperature range -170°C to 700°C, providing high sensitivity to thermal flow signals.
- Sample Pans/Supports: Platinum sample pans compatible with STA instruments, used for simultaneous mass change and heat flow measurements.
3. Consumable Maintenance
- Alumina crucibles are reusable but require periodic inspection for wear or contamination.
- Platinum consumables must avoid contact with corrosive gases and be thoroughly cleaned after use.
Why choose Labshopx thermal analysis consumables?
As a specialized supplier with 30 years of experience in Hitachi(Seiko) thermal analysis consumables, we offer the following advantages:
1.Superior Compatibility:Ensure the same performance as the original consumables
2.Customer Service:24/7 customer care
3.Competitive Pricing Structure:
- Set tiered pricing for clients who purchase many times
-
Offer regular promotions
4.Customization Capabilities:
- We propose customized suggestions according to the usage scenarios
- Small trial orders will also be accepted
-
Offer customized special dimensions/materials
Detailed Technical Specifications & Compatibility Guide
TGA (Thermogravimetric Analysis) Compatible Consumables
Alumina Crucibles - Enhanced Specifications:
Parameter | Specification | Compatible Part Numbers | Performance Benefits |
---|---|---|---|
Material Composition | Al₂O₃ 99.7% purity | GCA-0055, GCA-0020 | Minimal contamination, excellent baseline stability |
Operating Temperature | Room temp to 1600°C | All Hitachi TGA models | Wide analytical temperature range |
Volume Capacity | 15µL to 45µL | GAA-0064/0065, GAA-0068/0069 | Optimal sample size for accurate analysis |
Dimensional Tolerance | ±0.01mm | All compatible models | Perfect fit, consistent thermal contact |
Surface Finish | Ra < 0.4µm | All crucible types | Easy cleaning, reduced sample adhesion |
Platinum Crucibles - Premium Performance:
- Material Grade: 99.9% pure platinum for maximum chemical inertness
- Compatible Models: CSF-6411, and all high-temperature Hitachi TGA systems
- Temperature Capability: Continuous operation up to 1600°C
- Chemical Resistance: Inert to most aggressive samples and atmospheres
- Reusability: Extended lifecycle with proper handling and cleaning
- Thermal Conductivity: Excellent heat transfer for precise temperature control
DSC (Differential Scanning Calorimetry) Enhanced Specifications
DSC Sensors & Sample Pans - Advanced Features:
Sensor Technology:
- Thermocouple Type: Nickel-chromium/constantan differential design
- Operating Range: -170°C to 700°C with superior baseline stability
- Sensitivity: <0.1µW heat flow resolution
- Response Time: <2 seconds for rapid thermal events
- Atmosphere Compatibility: Inert, oxidizing, and reducing environments
Sample Pan Performance Features:
- Standard Aluminum Pans: 15µL and 45µL volumes for routine analysis
- Sealed Pan Systems: Pressure-tight design for volatile samples
- High-Pressure Capability: Up to 10 bar for pressurized DSC studies
- Thermal Contact Optimization: Flat-bottom design for maximum heat transfer
- Lid Sealing: Crimped and hermetic sealing options available
Comprehensive Hitachi (Seiko) Instrument Compatibility
Compatible Instrument Models & Part Number Cross-Reference
Instrument Model | Analysis Type | Our Compatible Part | Original Part Number | Volume/Size | Material Options |
---|---|---|---|---|---|
Hitachi STA 7200/7300 | Simultaneous TG-DSC | LX-HIT-STA-AL45 | GAA-0068/GAA-0069 | 45µL | Aluminum, Platinum, Ceramic |
Hitachi TG/DTA 7300 | TGA + DTA | LX-HIT-TGA-AL15 | GAA-0064/GAA-0065 | 15µL | Aluminum, Platinum |
Seiko DSC 6200/6300 | DSC | LX-HIT-DSC-GCA55 | GCA-0055 | 40µL | Aluminum, Sealed Aluminum |
Seiko TG/DTA 6200 | TGA + DTA | LX-HIT-PDS-GCA20 | GCA-0020 | Custom | Aluminum Plate |
Hitachi High-Temp TGA | High-Temperature TGA | LX-HIT-PT-CSF6411 | CSF-6411 | 60µL | Platinum, Ceramic |
Installation & Performance Verification
Quality Assurance Protocol:
- Dimensional Verification: CMM measurement against OEM samples
- Thermal Calibration: Temperature accuracy verification using standard materials
- Baseline Testing: Empty crucible thermal cycling for stability assessment
- Sample Testing: Comparative analysis with reference materials
- Long-term Stability: Extended use testing under analytical conditions
Advanced Application Guide & Analytical Best Practices
Specialized Analytical Applications
Pharmaceutical & Biomedical Applications:
Drug Stability Studies:
- Recommended Setup: Sealed aluminum pans for moisture-sensitive compounds
- Temperature Protocol: 10°C/min heating from 25°C to 300°C
- Atmosphere: Dry nitrogen purge at 50 mL/min
- Sample Size: 2-5mg for optimal sensitivity
Polymorphic Characterization:
- Crucible Choice: Standard aluminum pans for routine screening
- Heating Rates: Multiple rates (5, 10, 20°C/min) for kinetic analysis
- Controlled Cooling: 5°C/min cooling for recrystallization studies
Polymer & Materials Science Applications:
Thermal Degradation Analysis:
- TGA Setup: Platinum crucibles for high-temperature stability
- Atmosphere Control: Air, nitrogen, or oxygen depending on study requirements
- Heating Protocol: 20°C/min to 800°C for complete degradation
- Data Analysis: Multi-step decomposition kinetics modeling
Glass Transition & Melting Analysis:
- DSC Configuration: Standard aluminum pans with precise temperature control
- Heat-Cool-Heat Cycles: Eliminate thermal history effects
- Modulated DSC: Enhanced resolution for overlapping transitions
Industrial Quality Control Applications:
Routine Quality Testing:
- Standardized Procedures: Validated methods for batch-to-batch consistency
- Rapid Screening: High heating rates for quick assessment
- Automated Analysis: Compatible with auto-sampler systems
- Data Management: Integration with LIMS systems
Advanced Troubleshooting & Optimization
Baseline Issues & Solutions:
Baseline Drift Problems:
Symptoms: Gradual baseline shift during measurement
Root Causes: Contaminated crucibles, atmospheric moisture, instrument calibration
Solutions:
- Use fresh crucibles for each critical measurement
- Verify purge gas purity and flow rates (50-100 mL/min)
- Perform regular temperature and heat flow calibrations
- Check crucible seating and thermal contact
Peak Resolution Enhancement:
Improving Thermal Event Resolution:
- Sample Preparation: Uniform particle size <50µm
- Sample Mass Optimization: 2-10mg for DSC, 5-20mg for TGA
- Heating Rate Selection: Slower rates (5-10°C/min) for better resolution
- Atmosphere Selection: Inert for thermal transitions, reactive for decomposition
Comprehensive Cost-Benefit Analysis
Laboratory Cost Optimization Calculator
Laboratory Type | Monthly Usage | Consumable Mix | OEM Annual Cost | Compatible Annual Cost | Annual Savings | 3-Year Savings |
---|---|---|---|---|---|---|
Academic Research Lab | 50 crucibles + 20 accessories | 70% Al, 20% Ceramic, 10% Pt | $3,600 | $1,800 | $1,800 (50%) | $5,400 |
Pharmaceutical QC Lab | 200 crucibles + 50 accessories | 80% Al, 15% Ceramic, 5% Pt | $12,000 | $6,000 | $6,000 (50%) | $18,000 |
Materials Testing Lab | 150 crucibles + 75 accessories | 50% Al, 30% Ceramic, 20% Pt | $15,000 | $7,500 | $7,500 (50%) | $22,500 |
Industrial R&D Center | 500 crucibles + 100 accessories | 60% Al, 25% Ceramic, 15% Pt | $36,000 | $18,000 | $18,000 (50%) | $54,000 |
Return on Investment (ROI) Analysis
Beyond Cost Savings - Additional Value Propositions:
- Budget Reallocation: Redirect savings to advanced instrumentation and research
- Operational Flexibility: Reduced dependency on single suppliers
- Inventory Management: Simplified procurement with consolidated supplier
- Technical Support: Dedicated application specialists and troubleshooting
- Custom Solutions: Modified designs for specialized applications
- Bulk Pricing: Additional discounts for annual contracts and volume orders
Frequently Asked Questions - Hitachi (Seiko) Compatible Consumables
Are your compatible crucibles validated for regulatory compliance (FDA, ISO)?
Yes, our compatible consumables meet the same material and performance standards as original equipment. We provide certificates of analysis and compliance documentation suitable for regulated environments including pharmaceutical and medical device testing.
How do you ensure consistent quality across different production batches?
We implement comprehensive statistical process control including incoming material inspection, in-process monitoring, and final product verification. Each batch undergoes dimensional measurement, thermal testing, and material composition analysis before shipment.
Can I use your compatible consumables for method validation and transfer?
Absolutely. Our consumables are designed for seamless method transfer from OEM parts. We provide detailed technical documentation and can support method validation studies with comparative data demonstrating analytical equivalence.
What technical support do you provide for method development?
Our technical team offers comprehensive application support including crucible selection guidance, method optimization, troubleshooting assistance, and training on best practices for thermal analysis measurements.