UV Quartz Cuvettes
UV-VIS Quartz Cuvettes for Precision Spectrophotometry
Our UV-VIS quartz cuvettes are engineered for high-precision ultraviolet and visible light spectrophotometry. Manufactured from premium Japanese quartz glass, these cells provide exceptional optical clarity across the 190-1100nm wavelength range, making them essential for analytical chemistry, biochemistry, pharmaceutical analysis, and quality control applications.
Technical Specifications
🌈 Wavelength Range
190nm - 1100nm (UV-VIS)
Complete UV and visible spectrum coverage📏 Path Length Options
0.5mm - 90mm
Comprehensive range for all concentration levels💎 Material Quality
JGS1 Japanese Quartz Glass
Superior optical properties and chemical resistance🎯 Precision Standards
>80% Transmittance (Paired Testing)
Guaranteed accuracy for quantitative analysisUV-VIS Cuvette Path Length Selection Guide
Path Length | Volume | Best For | Typical Absorbance Range | Common Applications |
---|---|---|---|---|
0.5-1mm | 170μL-350μL | High concentration samples | 2.0-4.0 AU | Concentrated proteins, dyes |
2-3mm | 700μL-1.05mL | Medium-high concentrations | 1.0-2.0 AU | Enzyme assays, nucleic acids |
5mm | 1.75mL | Standard concentrations | 0.5-1.5 AU | Routine analytical work |
10mm | 3.5-4mL | Low-medium concentrations | 0.1-1.0 AU | Most common applications |
20-30mm | 7-10.5mL | Low concentrations | 0.05-0.5 AU | Trace analysis, dilute solutions |
40-90mm | 14-31.5mL | Very low concentrations | 0.01-0.2 AU | Environmental, pharmaceutical trace analysis |
UV-VIS Spectrophotometry Applications
🧬 Biochemistry & Life Sciences
- Protein concentration determination (A280)
- Nucleic acid quantification (A260/A280 ratio)
- Enzyme kinetics studies
- Cell growth monitoring (OD600)
- Bradford, BCA protein assays
💊 Pharmaceutical Analysis
- Drug purity testing
- Active ingredient quantification
- Dissolution testing
- Stability studies
- Impurity analysis
🏭 Industrial Quality Control
- Food and beverage analysis
- Chemical purity verification
- Color measurement
- Coating thickness analysis
- Raw material testing
🌍 Environmental Analysis
- Water quality monitoring
- Pollutant detection
- Soil contamination analysis
- Air quality assessment
- Heavy metals analysis
🔬 Research & Development
- Material characterization
- Reaction monitoring
- Catalyst evaluation
- Photochemistry studies
- Nanomaterial analysis
📚 Educational & Training
- Analytical chemistry courses
- Beer-Lambert law demonstrations
- Calibration curve exercises
- Method development training
- Instrumental analysis labs
UV-VIS Spectrophotometry Best Practices
Sample Preparation Guidelines
🧪 Solution Preparation
- Use appropriate solvents for your analyte
- Ensure complete dissolution
- Filter if necessary to remove particles
- Allow solutions to reach room temperature
📊 Concentration Selection
- Target absorbance: 0.2-0.8 AU for best accuracy
- Use shorter path lengths for concentrated samples
- Use longer path lengths for dilute samples
- Consider Beer-Lambert law limitations
🔬 Measurement Techniques
- Use matched cuvettes for comparative analysis
- Handle cuvettes by frosted sides only
- Fill cuvettes to appropriate level
- Check for air bubbles before measurement
3.5ml Quartz Fluorometer Flow 10mm Cuvette Closed Cells10mm | NEXACULE
NEXACULEDescription of quartz cell with tube: Type: quartz fluorescence cuvette Volume:3.5ml Material:Japanese Quartz Glass Path length:10mm Size:1...
View full details2pcs Quartz Cuvette Cells with Lid for Spectrophotometer Lab | NEXACULE
NEXACULEDescription of 2pcs quartz cell: Type: Quartz Cell /Cuvette Volume:1.05ml Material:Japanese Quartz Glass Path Length:3mm Technology:Glue b...
View full details1pcs Quartz Cuvette Cells JGS1 for Spectrophotometer Lab | NEXACULE
NEXACULEDescription of 170ul quartz cell: Type: Quartz Cell /Cuvette Volume:170ul Material:Japanese Quartz Glass Path Length:0.5mm Technology:Glue b...
View full detailsQuartz Cuvette Cells for AutomLAic Biochemical Analyzer 6mm | NEXACULE
NEXACULEType: Quartz Cuvette Volume:0.54ml Path length:6mm Transmittance:>80%(Paired testing) Outline dimension:7x8x27mm Technology:Solder frit ...
View full details10.5ml Quartz Cuvette with Lid 30mm Quartz UV Vis Cells | NEXACULE
NEXACULEType: Quartz Cuvette Volume:10.5ml Path length:30mm Transmittance:>80%(Paired testing) Outline dimension:12.5*32.5*45mm Technology:Glue ...
View full details21ml Quartz Cuvettes 60mm UV Vis Cuvette Quartz Cells | NEXACULE
NEXACULEType: Quartz Cuvette Volume:21ml Path length:60mm Transmittance:>80%(Paired testing) Outline dimension:12.5x62.5x45 mm Technology:Frit s...
View full details28ml Quartz Cuvettes 80mm Cells Spectrophotometry Cuvette | NEXACULE
NEXACULEType: Quartz Cuvette Volume:28ml Path length:80mm Transmittance:>80%(Paired testing) Outline dimension:12.5x82.5x45 mm Technology:Glue b...
View full detailsQuartz Cuvette with Lid 40mm UV Spectrophotometer Cuvette | NEXACULE
NEXACULEType: Quartz Cuvette Volume:14ml Path length:40mm Transmittance:>80%(Paired testing) Outline dimension:12.5x42.5x45 mm Technology:Glue b...
View full details24.5ml Quartz Cuvette 70mm Quartz Cell UV Spectrophotometer | NEXACULE
NEXACULEType: Quartz Cuvette Volume:24.5ml Path length:70mm Transmittance:>80%(Paired testing) Outline dimension:12.5x72.5x45 mm Technology:Glue...
View full detailsQuartz Cuvette 90mm Cells UV Spectrophotometer Cuvette | NEXACULE
NEXACULEType: Quartz Cuvette Volume:31.5ml Path length:90mm Transmittance:>80%(Paired testing) Outline dimension:12.5x92.5x45 mm Technology:Glue...
View full details28ml Quartz Cuvette 80mm UV Spectrophotometry Cells | NEXACULE
NEXACULEType: Quartz Cuvette Volume:28ml Path length:80mm Transmittance:>80%(Paired testing) Outline dimension:12.5x82.5x45 mm Technology:Glue b...
View full details21ml Quartz Cuvette 60mm UV Cuvettes Quartz Cells | NEXACULE
NEXACULEType: Quartz Cuvette Volume:21ml Path length:60mm Transmittance:>80%(Paired testing) Outline dimension:12.5x62.5x45 mm Technology:Frit s...
View full details7ml Quartz Cuvette with Lid 20mm Quartz Cells | NEXACULE
NEXACULEType: Quartz Cuvette Volume:7ml Path length:20mm Transmittance:>80%(Paired testing) Outline dimension:12.5x22.5x45 mm Material:Japanese ...
View full details1.05ml Quartz Cuvettes with Lid 3mm Quartz Cells | NEXACULE
NEXACULEType: Quartz Cuvette Volume:1.05ml Path length:3mm Transmittance:>80%(Paired testing) Outline dimension:12.5*5.5*45mm Material:Japanese ...
View full details4ml Standard Quartz Cuvette Cells 10mm with Lid | NEXACULE
NEXACULEType: Quartz Cuvette Volume:4ml Path length:10mm Transmittance:>80%(Paired testing) Outline dimension:13.5x14.5x43mm Technology:Solder f...
View full detailsQuartz Cuvettes UV Spectrophotometer Cuvettes Cells | NEXACULE
NEXACULEType: Quartz Cuvette Path length:10mm Transmittance:>80%(Paired testing) Outline dimension:12.5x12.5x44mm Technology:Two polished windows...
View full detailsQuartz Cuvette with Lid 5mm Quartz Cell Spectrophotometers | NEXACULE
NEXACULEType: Quartz Cuvette Volume:1.75ml Path length:5mm Transmittance:>80%(Paired testing) Outline dimension:12.5*7.5*45mm Technology:Glue Bo...
View full detailsQuartz Cuvette Quartz Cell UV Spectrophotometer Cuvette | NEXACULE
NEXACULEType: Quartz Cuvette Volume:350ul Path length:1mm Transmittance:>80%(Paired testing) Outline dimension:12.5*3.5*45mm Technology:Glue bon...
View full details10mm Quartz Scale Cells UV Spectrophotometer Cuvette | NEXACULE
NEXACULEType: Quartz Cuvette Volume:3.5ml Path length:10mm Outline dimension:12.5x12.5x45mm Technology:Solder frit bolding(Standard Transmittance/Hi...
View full details3.5ml Standard UV Quartz Cell with Lid and Leve bottom 10mm | NEXACULE
NEXACULEType: Quartz Cuvette Volume:3.5ml Path length:10mm Outline dimension:12.5x12.5x45mm Technology:Glue bonded/Standard Transmittance/High Trans...
View full detailsQuartz Cuvette Cells with Lid 20mm for Spectrophotometer Lab| NEXACULE
NEXACULEType: Quartz Cuvette Volume:7ml Outline dimension:12.5x22.5x45 mm Path length:20mm Technology:Glue bonded/Powder Fused/Optical Contact Bonde...
View full details3.5ml Standard Quartz Cell with Lid and Leve Bottom 10mm | NEXACULE
NEXACULEType: Quartz cuvette Volume:3.5ml Outline dimension:12.5x12.5x45mm Path length:5mm Technology:Optical contact bonding Transmittance:>80%...
View full details250ul Quartz Cuvette UV Cells 5mm Sample Cell for Lab | NEXACULE
NEXACULEType: Quartz cuvette (special requirement) Volume:250ul Outline dimension:7x7x15mm Path length:5mm Technology:Solder frit bolding Transmitta...
View full details20mm Quartz Cuvette Cells Large Area Photopermeability | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume:7ml Size:12.5x22.5x45mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable ...
View full detailsUV-VIS Quartz Cuvettes for Precision Spectrophotometry
Our UV-VIS quartz cuvettes are engineered for high-precision ultraviolet and visible light spectrophotometry. Manufactured from premium Japanese quartz glass, these cells provide exceptional optical clarity across the 190-1100nm wavelength range, making them essential for analytical chemistry, biochemistry, pharmaceutical analysis, and quality control applications.
Technical Specifications
🌈 Wavelength Range
190nm - 1100nm (UV-VIS)
Complete UV and visible spectrum coverage📏 Path Length Options
0.5mm - 90mm
Comprehensive range for all concentration levels💎 Material Quality
JGS1 Japanese Quartz Glass
Superior optical properties and chemical resistance🎯 Precision Standards
>80% Transmittance (Paired Testing)
Guaranteed accuracy for quantitative analysisUV-VIS Cuvette Path Length Selection Guide
Path Length | Volume | Best For | Typical Absorbance Range | Common Applications |
---|---|---|---|---|
0.5-1mm | 170μL-350μL | High concentration samples | 2.0-4.0 AU | Concentrated proteins, dyes |
2-3mm | 700μL-1.05mL | Medium-high concentrations | 1.0-2.0 AU | Enzyme assays, nucleic acids |
5mm | 1.75mL | Standard concentrations | 0.5-1.5 AU | Routine analytical work |
10mm | 3.5-4mL | Low-medium concentrations | 0.1-1.0 AU | Most common applications |
20-30mm | 7-10.5mL | Low concentrations | 0.05-0.5 AU | Trace analysis, dilute solutions |
40-90mm | 14-31.5mL | Very low concentrations | 0.01-0.2 AU | Environmental, pharmaceutical trace analysis |
UV-VIS Spectrophotometry Applications
🧬 Biochemistry & Life Sciences
- Protein concentration determination (A280)
- Nucleic acid quantification (A260/A280 ratio)
- Enzyme kinetics studies
- Cell growth monitoring (OD600)
- Bradford, BCA protein assays
💊 Pharmaceutical Analysis
- Drug purity testing
- Active ingredient quantification
- Dissolution testing
- Stability studies
- Impurity analysis
🏭 Industrial Quality Control
- Food and beverage analysis
- Chemical purity verification
- Color measurement
- Coating thickness analysis
- Raw material testing
🌍 Environmental Analysis
- Water quality monitoring
- Pollutant detection
- Soil contamination analysis
- Air quality assessment
- Heavy metals analysis
🔬 Research & Development
- Material characterization
- Reaction monitoring
- Catalyst evaluation
- Photochemistry studies
- Nanomaterial analysis
📚 Educational & Training
- Analytical chemistry courses
- Beer-Lambert law demonstrations
- Calibration curve exercises
- Method development training
- Instrumental analysis labs
UV-VIS Spectrophotometry Best Practices
Sample Preparation Guidelines
🧪 Solution Preparation
- Use appropriate solvents for your analyte
- Ensure complete dissolution
- Filter if necessary to remove particles
- Allow solutions to reach room temperature
📊 Concentration Selection
- Target absorbance: 0.2-0.8 AU for best accuracy
- Use shorter path lengths for concentrated samples
- Use longer path lengths for dilute samples
- Consider Beer-Lambert law limitations
🔬 Measurement Techniques
- Use matched cuvettes for comparative analysis
- Handle cuvettes by frosted sides only
- Fill cuvettes to appropriate level
- Check for air bubbles before measurement