UV Quartz Cuvettes
UV-VIS Quartz Cuvettes for Precision Spectrophotometry
Our UV-VIS quartz cuvettes are engineered for high-precision ultraviolet and visible light spectrophotometry. Manufactured from premium Japanese quartz glass, these cells provide exceptional optical clarity across the 190-1100nm wavelength range, making them essential for analytical chemistry, biochemistry, pharmaceutical analysis, and quality control applications.
Technical Specifications
🌈 Wavelength Range
190nm - 1100nm (UV-VIS)
Complete UV and visible spectrum coverage📏 Path Length Options
0.5mm - 90mm
Comprehensive range for all concentration levels💎 Material Quality
JGS1 Japanese Quartz Glass
Superior optical properties and chemical resistance🎯 Precision Standards
>80% Transmittance (Paired Testing)
Guaranteed accuracy for quantitative analysisUV-VIS Cuvette Path Length Selection Guide
Path Length | Volume | Best For | Typical Absorbance Range | Common Applications |
---|---|---|---|---|
0.5-1mm | 170μL-350μL | High concentration samples | 2.0-4.0 AU | Concentrated proteins, dyes |
2-3mm | 700μL-1.05mL | Medium-high concentrations | 1.0-2.0 AU | Enzyme assays, nucleic acids |
5mm | 1.75mL | Standard concentrations | 0.5-1.5 AU | Routine analytical work |
10mm | 3.5-4mL | Low-medium concentrations | 0.1-1.0 AU | Most common applications |
20-30mm | 7-10.5mL | Low concentrations | 0.05-0.5 AU | Trace analysis, dilute solutions |
40-90mm | 14-31.5mL | Very low concentrations | 0.01-0.2 AU | Environmental, pharmaceutical trace analysis |
UV-VIS Spectrophotometry Applications
🧬 Biochemistry & Life Sciences
- Protein concentration determination (A280)
- Nucleic acid quantification (A260/A280 ratio)
- Enzyme kinetics studies
- Cell growth monitoring (OD600)
- Bradford, BCA protein assays
💊 Pharmaceutical Analysis
- Drug purity testing
- Active ingredient quantification
- Dissolution testing
- Stability studies
- Impurity analysis
🏭 Industrial Quality Control
- Food and beverage analysis
- Chemical purity verification
- Color measurement
- Coating thickness analysis
- Raw material testing
🌍 Environmental Analysis
- Water quality monitoring
- Pollutant detection
- Soil contamination analysis
- Air quality assessment
- Heavy metals analysis
🔬 Research & Development
- Material characterization
- Reaction monitoring
- Catalyst evaluation
- Photochemistry studies
- Nanomaterial analysis
📚 Educational & Training
- Analytical chemistry courses
- Beer-Lambert law demonstrations
- Calibration curve exercises
- Method development training
- Instrumental analysis labs
UV-VIS Spectrophotometry Best Practices
Sample Preparation Guidelines
🧪 Solution Preparation
- Use appropriate solvents for your analyte
- Ensure complete dissolution
- Filter if necessary to remove particles
- Allow solutions to reach room temperature
📊 Concentration Selection
- Target absorbance: 0.2-0.8 AU for best accuracy
- Use shorter path lengths for concentrated samples
- Use longer path lengths for dilute samples
- Consider Beer-Lambert law limitations
🔬 Measurement Techniques
- Use matched cuvettes for comparative analysis
- Handle cuvettes by frosted sides only
- Fill cuvettes to appropriate level
- Check for air bubbles before measurement
16ml ChromLAic AberrLAion Quartz Cuvettes Cells10mm | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 16ml Size:32x14x62.5mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable ...
View full details7ml Quartz Cuvette UV Spectrophotometry Cuvette 5mm | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 7ml Size:45x7x45mm Path length:5mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable for:L...
View full details400ul Quartz Band Tube Cuvettes JGS1 Cells for Lab | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 400ul Size:12*12*58*138mm Slit:1mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-250...
View full details3.5ml Quartz Band Tube Cuvettes JGS1 Cell for Lab | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 3.5ml Size:12.5x12.5x45x95mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Sui...
View full details2 pcs Quartz Cuvette Cells100mm JGS1 for Spectrophotometer Lab | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 35ml Size:12.5x102.5x45mm Path length:100mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suita...
View full detailsQuartz Cuvette 2Ways UV Cells for Lab Square | NEXACULE
NEXACULEType: Quartz Cuvette Cell Size:35x5x42mm Path length:2mm/0.5mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable for:Laborato...
View full details3.5ml Malvern Quartz Cuvettes 10mm Cells for Lab | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 350ul Size:12x12x45 mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable ...
View full details70ul Quartz Cuvette 0.2mm Colorimetric Cuvette Cells | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 70ul Size:12.5x2.7x45 mm Path length:0.2mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitab...
View full details14ml Colorimetric Cuvette Quartz Cuvette with Screw Cap | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 14ml Size:12.5x42.5x45mm Path length:40mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitabl...
View full details700ul Quartz Cuvette Quartz Cells with Screw Cap | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 700ul Size:12.5x4.5x55mm Path length:2mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable...
View full detailsQuartz Cuvette Cells with Screw Cap Colorimetric Cuvette | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 350ul Size:12.5x3.5x55mm Path length:1mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable...
View full detailsQuartz Flow Cells Six-Way Light 50mm Colorimetric Dish | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 125ml Size:54x54x54mm Path length:50mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitable f...
View full detailsQuartz Cuvettes Standard Cells with lid and Round Bottom | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 3.5ml Size:12.5x12.5x45mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitab...
View full details700ul Quartz Cuvette with Lid Quartz Cell Spectrophotometers | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 700ul Size:12.5x4.5x45 mm Path length:2mm Technology:Glue Bonding Process/Frit Sintering/Fully Fution Mate...
View full details2 pcs Quartz Cuvette Cells10mm for Spectrophotometer Lab | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 3.5ml Size: 12.5x12.5x45mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suita...
View full detailsStandard Quartz Cuvettes 0.5mm Quartz Cells No lid | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 170ul Size: 12.5x3x45mm Path length:0.5mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitabl...
View full details3.5ml Standard Quartz Cuvettes Corrosion Resisting 2pcs | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 3.5ml Size: 12.5x12.5x45mm Path length:10mm Technology:Glue Bonding Process/Frit Sintering/Fully Fution M...
View full details35ml Quartz Cuvettes Cells UV Cuvette100mm for Lab | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 35ml Size: 12.5x12.5x45mm Path length:100mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suita...
View full details560ul Micro Quartz Cuvette with Lid 4mm Two Polished Windows| NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 560ul Size: 12.5x12.5x45mm Path length:4mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitab...
View full details10.5ml Quartz Glass Cuvette Two Polished Windows | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 10.5ML Size: 12.5x32.5x45mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suit...
View full details17.5mL Quartz Cuvette with Lid 50mm JGS1 Quartz Cell | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 17.5ML Size: 12.5x52.5x45mm Path length:50mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suit...
View full details14mL Quartz Cuvettes JGS1 Cells 10mm for Chemistry | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 14ML Size: 12.5x42.5x45mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suitab...
View full details3.5ml Quartz Cuvette Cell with Screw Cap 10mm for Chemistry | NEXACULE
NEXACULEType: Quartz Cuvette Cell Volume: 3.5ML Size: 12.5x12.5x55mm Path length:10mm Material:Japanese Quartz Glass Wave length:200nm-2500nm Suita...
View full details10mm Micro Quartz Cuvette with Lid 2 Sides Clear Cells | NEXACULE
NEXACULEType: Micro Quartz Cuvettes Volume: 350ul~1750ul Size: 12.5x12.5x55mm Slit width:1~5mm Path length:10mm Material:Japanese Quartz Glass Wave...
View full detailsUV-VIS Quartz Cuvettes for Precision Spectrophotometry
Our UV-VIS quartz cuvettes are engineered for high-precision ultraviolet and visible light spectrophotometry. Manufactured from premium Japanese quartz glass, these cells provide exceptional optical clarity across the 190-1100nm wavelength range, making them essential for analytical chemistry, biochemistry, pharmaceutical analysis, and quality control applications.
Technical Specifications
🌈 Wavelength Range
190nm - 1100nm (UV-VIS)
Complete UV and visible spectrum coverage📏 Path Length Options
0.5mm - 90mm
Comprehensive range for all concentration levels💎 Material Quality
JGS1 Japanese Quartz Glass
Superior optical properties and chemical resistance🎯 Precision Standards
>80% Transmittance (Paired Testing)
Guaranteed accuracy for quantitative analysisUV-VIS Cuvette Path Length Selection Guide
Path Length | Volume | Best For | Typical Absorbance Range | Common Applications |
---|---|---|---|---|
0.5-1mm | 170μL-350μL | High concentration samples | 2.0-4.0 AU | Concentrated proteins, dyes |
2-3mm | 700μL-1.05mL | Medium-high concentrations | 1.0-2.0 AU | Enzyme assays, nucleic acids |
5mm | 1.75mL | Standard concentrations | 0.5-1.5 AU | Routine analytical work |
10mm | 3.5-4mL | Low-medium concentrations | 0.1-1.0 AU | Most common applications |
20-30mm | 7-10.5mL | Low concentrations | 0.05-0.5 AU | Trace analysis, dilute solutions |
40-90mm | 14-31.5mL | Very low concentrations | 0.01-0.2 AU | Environmental, pharmaceutical trace analysis |
UV-VIS Spectrophotometry Applications
🧬 Biochemistry & Life Sciences
- Protein concentration determination (A280)
- Nucleic acid quantification (A260/A280 ratio)
- Enzyme kinetics studies
- Cell growth monitoring (OD600)
- Bradford, BCA protein assays
💊 Pharmaceutical Analysis
- Drug purity testing
- Active ingredient quantification
- Dissolution testing
- Stability studies
- Impurity analysis
🏭 Industrial Quality Control
- Food and beverage analysis
- Chemical purity verification
- Color measurement
- Coating thickness analysis
- Raw material testing
🌍 Environmental Analysis
- Water quality monitoring
- Pollutant detection
- Soil contamination analysis
- Air quality assessment
- Heavy metals analysis
🔬 Research & Development
- Material characterization
- Reaction monitoring
- Catalyst evaluation
- Photochemistry studies
- Nanomaterial analysis
📚 Educational & Training
- Analytical chemistry courses
- Beer-Lambert law demonstrations
- Calibration curve exercises
- Method development training
- Instrumental analysis labs
UV-VIS Spectrophotometry Best Practices
Sample Preparation Guidelines
🧪 Solution Preparation
- Use appropriate solvents for your analyte
- Ensure complete dissolution
- Filter if necessary to remove particles
- Allow solutions to reach room temperature
📊 Concentration Selection
- Target absorbance: 0.2-0.8 AU for best accuracy
- Use shorter path lengths for concentrated samples
- Use longer path lengths for dilute samples
- Consider Beer-Lambert law limitations
🔬 Measurement Techniques
- Use matched cuvettes for comparative analysis
- Handle cuvettes by frosted sides only
- Fill cuvettes to appropriate level
- Check for air bubbles before measurement