Thermal Analysis Consumables
Professional Thermal Analysis Consumables for Research & Industry
Thermal analysis is a cornerstone of materials science, quality control, and research across industries including pharmaceuticals, polymers, metals, ceramics, and food science. Our comprehensive selection of thermal analysis consumables supports DSC (Differential Scanning Calorimetry), TGA (Thermogravimetric Analysis), STA (Simultaneous Thermal Analysis), and DMA (Dynamic Mechanical Analysis) applications.
Industry-Leading Compatibility Across All Major Brands
We provide premium-quality consumables compatible with thermal analysis instruments from TA Instruments, PerkinElmer, Netzsch, Mettler Toledo, Shimadzu, Setaram, Hitachi, Rigaku, Linseis, and LECO. Each product is manufactured to exact OEM specifications while offering significant cost savings without compromising analytical precision.
Material Science Excellence
Premium Material Options:
- Aluminum: Standard choice for DSC analysis (-180°C to 600°C), excellent thermal conductivity
- Platinum: Ultimate high-temperature performance (up to 1000°C), superior oxidation resistance
- Ceramic (Alumina): Inert environment analysis, high thermal stability, corrosion resistance
- Stainless Steel: Medium-temperature applications, mechanical durability
- Graphite: Specialized high-temperature applications, unique thermal properties
- Quartz: Ultra-pure analysis, minimal sample interaction
Application-Specific Solutions
Pharmaceutical Industry:
Tzero aluminum pans for precise melting point determination, polymorphism studies, and stability testing. Hermetic sealing options prevent moisture interference in hygroscopic samples.
Polymer Research:
High-volume aluminum crucibles for glass transition temperature measurement, crystallization kinetics, and thermal stability evaluation across diverse polymer matrices.
Metals & Alloys:
Platinum and ceramic crucibles for high-temperature phase transition analysis, oxidation studies, and compositional analysis in metallurgical research.
Food Science:
Specialized aluminum pans for moisture analysis, fat content determination, and thermal processing optimization in food product development.
Quality Assurance & Certification
Every batch undergoes comprehensive quality testing including dimensional verification, material composition analysis, thermal performance validation, and surface finish inspection. Our products meet international standards (ISO, ASTM) and are certified for use in regulated environments including FDA-compliant laboratories.
Thermal Analysis Brand Compatibility Guide
Leading Thermal Analysis Brands Overview:
TA Instruments - Global Market Leader
Specialties: Q-Series DSC, Discovery TGA, Tzero technology
Key Features: Advanced baseline stability, high sensitivity
Popular Models: Q2000, Q5000, DSC25, TGA5500
Sample Requirements: Tzero aluminum pans, platinum crucibles
PerkinElmer - Analytical Excellence
Specialties: STA systems, simultaneous DSC-TGA
Key Features: Integrated analysis, rapid heating rates
Popular Models: STA6000, STA8000, DSC8000, TGA8000
Sample Requirements: Ceramic pans, aluminum crucibles
Netzsch - German Engineering
Specialties: High-temperature analysis, Jupiter STA
Key Features: Exceptional temperature accuracy, robust design
Popular Models: DSC214, STA449, TG209
Sample Requirements: Concavus pans, alumina crucibles
Mettler Toledo - Precision Instruments
Specialties: STAR system, automated sampling
Key Features: Outstanding reproducibility, user-friendly software
Popular Models: DSC3+, TGA2, DSC823e
Sample Requirements: Standard aluminum crucibles, ceramic options
Technical Selection Guide for Optimal Results
Temperature Range Considerations:
Temperature Range | Recommended Materials | Typical Applications |
---|---|---|
-180°C to 400°C | Aluminum, Stainless Steel | Polymer analysis, pharmaceutical studies |
400°C to 700°C | Ceramic (Alumina), Platinum | High-temperature polymers, composites |
700°C to 1000°C | Platinum, High-purity Alumina | Metals, ceramics, catalyst studies |
Above 1000°C | Platinum, Graphite | Refractory materials, advanced ceramics |
Atmosphere Compatibility:
- Inert Atmosphere (N₂, Ar): All materials suitable
- Oxidizing Atmosphere (Air, O₂): Aluminum, Platinum, Ceramic recommended
- Reducing Atmosphere (H₂): Platinum, Ceramic, avoid aluminum at high temperatures
- Corrosive Environments: Platinum, high-purity alumina ceramic
Sample Preparation Best Practices:
- Optimal sample mass: 5-15mg for DSC, 10-50mg for TGA
- Ensure uniform sample distribution for consistent heat transfer
- Consider particle size effects on thermal response
- Use appropriate lid sealing for hermetic or vented analysis
- Clean crucibles thoroughly between uses to prevent contamination
Thermal Analysis Consumables FAQ
Q: How do I choose the right crucible material for my thermal analysis?
A: Material selection depends on your analysis requirements:
• Aluminum: Best for DSC analysis (-180°C to 600°C), polymer studies, pharmaceutical applications
• Platinum: Essential for high-temperature TGA (up to 1000°C), oxidation studies, catalyst analysis
• Ceramic (Alumina): Ideal for chemically reactive samples, corrosive materials, high-temperature stability
• Stainless Steel: Good for medium-temperature applications requiring mechanical strength
Q: What's the difference between standard and Tzero aluminum pans?
A: Tzero technology from TA Instruments features:
• Enhanced thermal contact between pan and sensor
• Improved baseline flatness and sensitivity
• Better resolution for closely spaced thermal events
• Optimal for precise DSC measurements requiring maximum accuracy
Q: Are your consumables fully compatible with OEM specifications?
A: Yes, our consumables are manufactured to exact OEM dimensional and material specifications. We guarantee:
• Precise dimensional accuracy (±0.01mm tolerance)
• Material composition verification
• Thermal performance equivalence
• Full compatibility with all major thermal analysis instruments
Q: How much can I save compared to OEM consumables?
A: Our compatible consumables typically offer:
• 30-50% cost savings compared to OEM prices
• Bulk purchasing discounts for high-volume users
• Same analytical performance and reliability
• Comprehensive quality certification
Q: What quality certifications do your thermal analysis consumables have?
A: All products undergo rigorous quality control:
• ISO 9001:2015 quality management certification
• Material composition analysis (Certificate of Analysis available)
• Dimensional verification testing
• Thermal performance validation
• Batch traceability for regulatory compliance
Q: Which crucible volume should I choose for my samples?
A: Volume selection guidelines:
• 20-40μl: Standard for DSC analysis, small sample sizes
• 90-100μl: TGA applications, larger sample requirements
• 150-250μl: STA simultaneous analysis, bulk samples
• Consider sample density and thermal conductivity for optimal results
35μl Aluminum Crucible with Lid for Netzsch NGB810419/NGB8104 for Netzsch Aluminium Sample Pans | NEXACULE
NEXACULEType Sample pan/crucible with lid Suitable for Netzsch Part NO A-NE-33 same design as Netzsch NGB810419/NGB810420 Volume 35μl Lid ...
View full details190μl Platinum Sample Pan With Lid Same Size As NGB801556/GB399860 for Netzsch PT Crucibles | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch DSC 204 F1 Phoenix®, DSC 200 F3 Maia®, DSC 3500 Sirius and DSC 214 Polyma, TG 209 ...
View full details75ul PT Sample Pans with Lids Size D7*2.4mm for Netzsch Platinum Crucible | NEXACULE
NEXACULEType Sample pan /crucible with lid Part NO A-NE-42 for Netzsch Capacity 75ul Lid With Material PT/RH Platinum Stocking time 1-7 w...
View full details85μl Copper Crucibles with Lids Size D6.8*4mm for Netzsch Copper Sample Pan | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part NO A-NE-43 Capacity 85ul Lid With Pin No Material Copper Stocking...
View full details27μl Reusable High Pressure Crucible with Lid and Seal for Netzsch 6.239.2-92.3.00 | NEXACULE
NEXACULEType High pressure crucible(with lid/seal) Suitable for Netzsch Part NO A-NE-45 same design as Netzsch 6.239.2-93.3.00 Matching Pan ki...
View full details100μl Reusable High Pressure Sample Crucible with Lid and Seal for Netzsch 6.239.2-93.4.00 | NEXACULE
NEXACULEType High pressure crucible(with lid/seal) Suitable for Netzsch Part NO A-NE-46 one crucible with lid with one seal ,equivalent to Netzsch...
View full details50μl Alumina Crucible with Flat Base for PerkinElmer/PE DuPont TGA Ceramic Pans | NEXACULE
NEXACULEType Sample pan /crucible PE TGA & DSC Suitable for PE DuPont Part NO A-PA-132 Volume μL 50μl Lid Without Material Alumina Cera...
View full details60μl Alumina Sample Cups with Round Bottom for PE 04190387 for PerkinElmer/PE Ceramic Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for PE DTA7 and DTA1700, DuPont Part NO A-PA-133 same design as PE-04190387 Volume μL 60μl Lid Wit...
View full details40μl Alumina Crucible with Lid for PE N5190180 for PerkinElmer/PE Ceramic Pans | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for PE Part NO A-PA-133-1 same design as PE N5190180 Capacity 40μl Lid With Material A...
View full details60μl Inner Alumina Crucible with Lid for PE N5200040 N5200045 for PerkinElmer/PE| NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Ceramic Sample Pans PE N5200040 N5200045 Size D5*4.6*0.4mm Part No. A-PA-135 Lid Wit...
View full details250μl Graphite Sample Pan Same Size as PE-N5200045 PerkinElmer Thermal Analysis Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for PE TGA6/As6 STA 8000, TGA 4000, STA 6000 Part NO Size...
View full detailsAlumina Sample Pan Stirrup for PerkinElmer/PE TGA 8000 Thermal Analysis Consumables/Tool | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Perkin Elmer TGA 8000 Part NO A-PA-136-1 Volume μL / Handle With Material Alumina Ceramic ...
View full details40μl Graphite Sample Pans and Covers for PE 03190025 for PerkinElmer/PE Graphite Crucibles Thermal Analysis Consumables | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for PE PE 03190025 | For PerkinElmer DSC 6000, DSC 8000, Pyris 1 DSC, Jade DSC, DSC 4000, Di...
View full detailsPlatinum Stirrup Kit PE 03190265 for PerkinElmer/PE TGA 7 PYRIS 1 Pt Stirrups | NEXACULE
NEXACULEType Stirrup kit Suitable for PE GA 7, PYRIS 1 Part NO A-PP-137-1 same design as PE 03190265 Temperature Range :-150~1600℃ Match cru...
View full details45ul Platinum Sample Pans for PE N5356016 for PerkinElmer/PE PT Crucibles | NEXACULE
NEXACULEType Sample pan /crucible Suitable for PerkinElmer TGA6/As6 STA 8000,TGA 4000,STA 6000 Part NO A-PA-134-5 same design as PE N5356016 T...
View full detailsPlatinum/PT Crucible D5*H4mm for PerKinElmer/PE Platinum Pans Thermal Analysis Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for PE Part No. A-PA-134-6 Size D5*4mm Temperature Range :-150~1600℃ Lid Without |If need lid c...
View full detailsPlatinum Lids Size D5mm for PerKinElmer/PE Platinum Sample Pans Thermal Analysis Consumables | NEXACULE
NEXACULEType lid Suitable for PE Size D5mm Part No. A-PA-134-7 Temperature Range :-150~1600℃ Matching crucible Platinum/PT Crucible D5*H4m...
View full detailsVented Platinum Sample Holder Covers for PE 04190299 for PerKinElmer/PE Thermal analysis consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for PerKinElmer Diamond DSC, DSC 8000 and DSC 8500 sample holders Part No. A-PE-17 equivalent to PE 041...
View full detailsPlatinum Sample Pan Kit with Stirrup for PE-N5190280 for PerKinElmer PT Crucibles Thermal Analysis Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for PE Part No. A-PE-18 same design as PE-N5190280 Lid Without Material PLATINUM Stocking time ...
View full detailsPlatinum Hangdown Wire Kit for PE N5190276 for PerkinElmer/PE Thermal Analysis Consumables | NEXACULE
NEXACULEItem Hangdown Suitable for PerkinElmer DSC 8000 Part No. A-PE-19 same design as PE N5190276 Material Platinum Stocking time 1-7 work...
View full details30μl Reusable Stainless Steel High Pressure Capsules for PE B0182901 for PerKinElmer/PE with Seal | NEXACULE
NEXACULEType Reusable Capsules and Copper seals Suitable for PE DSC 4000, DSC 6000, DSC 8000, DSC 8500, Diamond DSC, Pyris 1 DSC, DSC 7, DSC 6, Pyri...
View full detailsGold Plated Copper Sealing Disks for PE B0182905 for PerkinElmer/PE | NEXACULE
NEXACULEType seals/disk Suitable for PE DSC 6000, DSC 8000, Pyris 1 DSC, Jade DSC, DSC 4000, Diamond DSC, DSC 6, DSC 8500, Pyris 6 DSC, DSC 7 ...
View full details30μl Gold Plated Stainless Steel High Pressure Capsules for PE B0182902 for PerkinElmer/PE | NEXACULE
NEXACULEType Reusable Capsules Suitable for PE DSC 6/7/4000/6000/8000/8500/Jade DSC/Diamond DSC/PYRIS 1 DSC/PYRIS 6 DSC Part NO A-PE-23 same design...
View full detailsHigh Pressure Capsule Sealing Tool for PE B0182864 for PerkinElmer/PE (OEM Design) | NEXACULE
NEXACULEType Sample pan /crucible sealing press Suitable for For PE High Pressure Crucible Part NO A-PP-137-9 same design as PE-B0182864 Set ...
View full detailsProfessional Thermal Analysis Consumables for Research & Industry
Thermal analysis is a cornerstone of materials science, quality control, and research across industries including pharmaceuticals, polymers, metals, ceramics, and food science. Our comprehensive selection of thermal analysis consumables supports DSC (Differential Scanning Calorimetry), TGA (Thermogravimetric Analysis), STA (Simultaneous Thermal Analysis), and DMA (Dynamic Mechanical Analysis) applications.
Industry-Leading Compatibility Across All Major Brands
We provide premium-quality consumables compatible with thermal analysis instruments from TA Instruments, PerkinElmer, Netzsch, Mettler Toledo, Shimadzu, Setaram, Hitachi, Rigaku, Linseis, and LECO. Each product is manufactured to exact OEM specifications while offering significant cost savings without compromising analytical precision.
Material Science Excellence
Premium Material Options:
- Aluminum: Standard choice for DSC analysis (-180°C to 600°C), excellent thermal conductivity
- Platinum: Ultimate high-temperature performance (up to 1000°C), superior oxidation resistance
- Ceramic (Alumina): Inert environment analysis, high thermal stability, corrosion resistance
- Stainless Steel: Medium-temperature applications, mechanical durability
- Graphite: Specialized high-temperature applications, unique thermal properties
- Quartz: Ultra-pure analysis, minimal sample interaction
Application-Specific Solutions
Pharmaceutical Industry:
Tzero aluminum pans for precise melting point determination, polymorphism studies, and stability testing. Hermetic sealing options prevent moisture interference in hygroscopic samples.
Polymer Research:
High-volume aluminum crucibles for glass transition temperature measurement, crystallization kinetics, and thermal stability evaluation across diverse polymer matrices.
Metals & Alloys:
Platinum and ceramic crucibles for high-temperature phase transition analysis, oxidation studies, and compositional analysis in metallurgical research.
Food Science:
Specialized aluminum pans for moisture analysis, fat content determination, and thermal processing optimization in food product development.
Quality Assurance & Certification
Every batch undergoes comprehensive quality testing including dimensional verification, material composition analysis, thermal performance validation, and surface finish inspection. Our products meet international standards (ISO, ASTM) and are certified for use in regulated environments including FDA-compliant laboratories.
Thermal Analysis Brand Compatibility Guide
Leading Thermal Analysis Brands Overview:
TA Instruments - Global Market Leader
Specialties: Q-Series DSC, Discovery TGA, Tzero technology
Key Features: Advanced baseline stability, high sensitivity
Popular Models: Q2000, Q5000, DSC25, TGA5500
Sample Requirements: Tzero aluminum pans, platinum crucibles
PerkinElmer - Analytical Excellence
Specialties: STA systems, simultaneous DSC-TGA
Key Features: Integrated analysis, rapid heating rates
Popular Models: STA6000, STA8000, DSC8000, TGA8000
Sample Requirements: Ceramic pans, aluminum crucibles
Netzsch - German Engineering
Specialties: High-temperature analysis, Jupiter STA
Key Features: Exceptional temperature accuracy, robust design
Popular Models: DSC214, STA449, TG209
Sample Requirements: Concavus pans, alumina crucibles
Mettler Toledo - Precision Instruments
Specialties: STAR system, automated sampling
Key Features: Outstanding reproducibility, user-friendly software
Popular Models: DSC3+, TGA2, DSC823e
Sample Requirements: Standard aluminum crucibles, ceramic options
Technical Selection Guide for Optimal Results
Temperature Range Considerations:
Temperature Range | Recommended Materials | Typical Applications |
---|---|---|
-180°C to 400°C | Aluminum, Stainless Steel | Polymer analysis, pharmaceutical studies |
400°C to 700°C | Ceramic (Alumina), Platinum | High-temperature polymers, composites |
700°C to 1000°C | Platinum, High-purity Alumina | Metals, ceramics, catalyst studies |
Above 1000°C | Platinum, Graphite | Refractory materials, advanced ceramics |
Atmosphere Compatibility:
- Inert Atmosphere (N₂, Ar): All materials suitable
- Oxidizing Atmosphere (Air, O₂): Aluminum, Platinum, Ceramic recommended
- Reducing Atmosphere (H₂): Platinum, Ceramic, avoid aluminum at high temperatures
- Corrosive Environments: Platinum, high-purity alumina ceramic
Sample Preparation Best Practices:
- Optimal sample mass: 5-15mg for DSC, 10-50mg for TGA
- Ensure uniform sample distribution for consistent heat transfer
- Consider particle size effects on thermal response
- Use appropriate lid sealing for hermetic or vented analysis
- Clean crucibles thoroughly between uses to prevent contamination
Thermal Analysis Consumables FAQ
Q: How do I choose the right crucible material for my thermal analysis?
A: Material selection depends on your analysis requirements:
• Aluminum: Best for DSC analysis (-180°C to 600°C), polymer studies, pharmaceutical applications
• Platinum: Essential for high-temperature TGA (up to 1000°C), oxidation studies, catalyst analysis
• Ceramic (Alumina): Ideal for chemically reactive samples, corrosive materials, high-temperature stability
• Stainless Steel: Good for medium-temperature applications requiring mechanical strength
Q: What's the difference between standard and Tzero aluminum pans?
A: Tzero technology from TA Instruments features:
• Enhanced thermal contact between pan and sensor
• Improved baseline flatness and sensitivity
• Better resolution for closely spaced thermal events
• Optimal for precise DSC measurements requiring maximum accuracy
Q: Are your consumables fully compatible with OEM specifications?
A: Yes, our consumables are manufactured to exact OEM dimensional and material specifications. We guarantee:
• Precise dimensional accuracy (±0.01mm tolerance)
• Material composition verification
• Thermal performance equivalence
• Full compatibility with all major thermal analysis instruments
Q: How much can I save compared to OEM consumables?
A: Our compatible consumables typically offer:
• 30-50% cost savings compared to OEM prices
• Bulk purchasing discounts for high-volume users
• Same analytical performance and reliability
• Comprehensive quality certification
Q: What quality certifications do your thermal analysis consumables have?
A: All products undergo rigorous quality control:
• ISO 9001:2015 quality management certification
• Material composition analysis (Certificate of Analysis available)
• Dimensional verification testing
• Thermal performance validation
• Batch traceability for regulatory compliance
Q: Which crucible volume should I choose for my samples?
A: Volume selection guidelines:
• 20-40μl: Standard for DSC analysis, small sample sizes
• 90-100μl: TGA applications, larger sample requirements
• 150-250μl: STA simultaneous analysis, bulk samples
• Consider sample density and thermal conductivity for optimal results