Skip to content
Free shipping all over the store
Free shipping all over the store

Thermal Analysis Consumables

Professional Thermal Analysis Consumables for Research & Industry

Thermal analysis is a cornerstone of materials science, quality control, and research across industries including pharmaceuticals, polymers, metals, ceramics, and food science. Our comprehensive selection of thermal analysis consumables supports DSC (Differential Scanning Calorimetry), TGA (Thermogravimetric Analysis), STA (Simultaneous Thermal Analysis), and DMA (Dynamic Mechanical Analysis) applications.

Industry-Leading Compatibility Across All Major Brands

We provide premium-quality consumables compatible with thermal analysis instruments from TA Instruments, PerkinElmer, Netzsch, Mettler Toledo, Shimadzu, Setaram, Hitachi, Rigaku, Linseis, and LECO. Each product is manufactured to exact OEM specifications while offering significant cost savings without compromising analytical precision.

Material Science Excellence

Premium Material Options:

  • Aluminum: Standard choice for DSC analysis (-180°C to 600°C), excellent thermal conductivity
  • Platinum: Ultimate high-temperature performance (up to 1000°C), superior oxidation resistance
  • Ceramic (Alumina): Inert environment analysis, high thermal stability, corrosion resistance
  • Stainless Steel: Medium-temperature applications, mechanical durability
  • Graphite: Specialized high-temperature applications, unique thermal properties
  • Quartz: Ultra-pure analysis, minimal sample interaction

Application-Specific Solutions

Pharmaceutical Industry:

Tzero aluminum pans for precise melting point determination, polymorphism studies, and stability testing. Hermetic sealing options prevent moisture interference in hygroscopic samples.

Polymer Research:

High-volume aluminum crucibles for glass transition temperature measurement, crystallization kinetics, and thermal stability evaluation across diverse polymer matrices.

Metals & Alloys:

Platinum and ceramic crucibles for high-temperature phase transition analysis, oxidation studies, and compositional analysis in metallurgical research.

Food Science:

Specialized aluminum pans for moisture analysis, fat content determination, and thermal processing optimization in food product development.

Quality Assurance & Certification

Every batch undergoes comprehensive quality testing including dimensional verification, material composition analysis, thermal performance validation, and surface finish inspection. Our products meet international standards (ISO, ASTM) and are certified for use in regulated environments including FDA-compliant laboratories.

Thermal Analysis Brand Compatibility Guide

Leading Thermal Analysis Brands Overview:

TA Instruments - Global Market Leader

Specialties: Q-Series DSC, Discovery TGA, Tzero technology
Key Features: Advanced baseline stability, high sensitivity
Popular Models: Q2000, Q5000, DSC25, TGA5500
Sample Requirements: Tzero aluminum pans, platinum crucibles

PerkinElmer - Analytical Excellence

Specialties: STA systems, simultaneous DSC-TGA
Key Features: Integrated analysis, rapid heating rates
Popular Models: STA6000, STA8000, DSC8000, TGA8000
Sample Requirements: Ceramic pans, aluminum crucibles

Netzsch - German Engineering

Specialties: High-temperature analysis, Jupiter STA
Key Features: Exceptional temperature accuracy, robust design
Popular Models: DSC214, STA449, TG209
Sample Requirements: Concavus pans, alumina crucibles

Mettler Toledo - Precision Instruments

Specialties: STAR system, automated sampling
Key Features: Outstanding reproducibility, user-friendly software
Popular Models: DSC3+, TGA2, DSC823e
Sample Requirements: Standard aluminum crucibles, ceramic options

Technical Selection Guide for Optimal Results

Temperature Range Considerations:

Temperature Range Recommended Materials Typical Applications
-180°C to 400°C Aluminum, Stainless Steel Polymer analysis, pharmaceutical studies
400°C to 700°C Ceramic (Alumina), Platinum High-temperature polymers, composites
700°C to 1000°C Platinum, High-purity Alumina Metals, ceramics, catalyst studies
Above 1000°C Platinum, Graphite Refractory materials, advanced ceramics

Atmosphere Compatibility:

  • Inert Atmosphere (N₂, Ar): All materials suitable
  • Oxidizing Atmosphere (Air, O₂): Aluminum, Platinum, Ceramic recommended
  • Reducing Atmosphere (H₂): Platinum, Ceramic, avoid aluminum at high temperatures
  • Corrosive Environments: Platinum, high-purity alumina ceramic

Sample Preparation Best Practices:

  • Optimal sample mass: 5-15mg for DSC, 10-50mg for TGA
  • Ensure uniform sample distribution for consistent heat transfer
  • Consider particle size effects on thermal response
  • Use appropriate lid sealing for hermetic or vented analysis
  • Clean crucibles thoroughly between uses to prevent contamination

Thermal Analysis Consumables FAQ

Q: How do I choose the right crucible material for my thermal analysis?

A: Material selection depends on your analysis requirements:
Aluminum: Best for DSC analysis (-180°C to 600°C), polymer studies, pharmaceutical applications
Platinum: Essential for high-temperature TGA (up to 1000°C), oxidation studies, catalyst analysis
Ceramic (Alumina): Ideal for chemically reactive samples, corrosive materials, high-temperature stability
Stainless Steel: Good for medium-temperature applications requiring mechanical strength

Q: What's the difference between standard and Tzero aluminum pans?

A: Tzero technology from TA Instruments features:
• Enhanced thermal contact between pan and sensor
• Improved baseline flatness and sensitivity
• Better resolution for closely spaced thermal events
• Optimal for precise DSC measurements requiring maximum accuracy

Q: Are your consumables fully compatible with OEM specifications?

A: Yes, our consumables are manufactured to exact OEM dimensional and material specifications. We guarantee:
• Precise dimensional accuracy (±0.01mm tolerance)
• Material composition verification
• Thermal performance equivalence
• Full compatibility with all major thermal analysis instruments

Q: How much can I save compared to OEM consumables?

A: Our compatible consumables typically offer:
• 30-50% cost savings compared to OEM prices
• Bulk purchasing discounts for high-volume users
• Same analytical performance and reliability
• Comprehensive quality certification

Q: What quality certifications do your thermal analysis consumables have?

A: All products undergo rigorous quality control:
• ISO 9001:2015 quality management certification
• Material composition analysis (Certificate of Analysis available)
• Dimensional verification testing
• Thermal performance validation
• Batch traceability for regulatory compliance

Q: Which crucible volume should I choose for my samples?

A: Volume selection guidelines:
20-40μl: Standard for DSC analysis, small sample sizes
90-100μl: TGA applications, larger sample requirements
150-250μl: STA simultaneous analysis, bulk samples
• Consider sample density and thermal conductivity for optimal results

 

30μl Platinum Crucible Small With Lid for ME-51140842 for Mettler Toledo/Mettler PT Sample Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$380.00
$380.00 - $380.00
Current price $380.00
in stock

  Type PT Crucible for DSC/TGA/sample robot Suitable for A-M-32 same design as Mettler  ME-51140842 Size 30ul Material Platinum Matc...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$380.00
$380.00 - $380.00
Current price $380.00

70μl Platinum Crucible W/Lid for ME-51119654 for Mettler Toledo/Mettler PT Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$437.00 - $1,083.00
$437.00 - $1,083.00
Current price $437.00
in stock

  Type Pt Crucible with lid  Suitable for Mettler DSC/TGA/sample robot Part NO. A-M-33 same design as ME-51119654 Capacity 70ul  Mater...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$437.00 - $1,083.00
$437.00 - $1,083.00
Current price $437.00

150μl Platinum Crucible Without Pin With Lid for ME-00024126 for Mettler Toledo/Mettler PT Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$408.50 - $1,406.00
$408.50 - $1,406.00
Current price $408.50
in stock

  Type Sample pan and lid Part No. A-M-34 same design as ME-00024126 Volume 150ul Material Platinum Matching disk sapphire disk (000...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$408.50 - $1,406.00
$408.50 - $1,406.00
Current price $408.50

Sapphire Disk/Disc D7.0mm T0.16mm for ME-00017759 for Mettler Toledo/Mettler DSC Consumables | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$190.00 - $478.80
$190.00 - $478.80
Current price $190.00
in stock

Type Disc Suitable for Mettler  Part No. A-M-35 equivalent to  ME-00017759 Match with 150ul Platinum Crucible ME-00024126,70ul ...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$190.00 - $478.80
$190.00 - $478.80
Current price $190.00

Sapphire Specific Heat Slices D4.8mm T0.33mm for Mettler Toledo/Mettler Thermal Analysis Consumables | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$156.75 - $371.93
$156.75 - $371.93
Current price $156.75
in stock

Type Sapphire specific heat slices Suitable for Mettler  Part NO. A-MB-021-4 for Mettler Toledo Size D:4.8mm T:0.33mm W:20mg ,Use ...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$156.75 - $371.93
$156.75 - $371.93
Current price $156.75

25μl Netzsch Alumina Crucibles D7*2mm for Netzsch Ceramic Pans DSC Consumables Al2O3 Pan | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$95.00 - $346.75
$95.00 - $346.75
Current price $95.00
in stock

Typea Sample pan /crucible Suitable for Netzsch Part NO A-NE-1   Volume μL 25 μL Size D7*2MM Lid  Without Material Alumina Ceramic...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$95.00 - $346.75
$95.00 - $346.75
Current price $95.00

25μl Alumina Crucibles D7.5*2mm for Netzsch Ceramic Pans Thermal Analysis Consumables Al2O3 Pan | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$95.00 - $346.75
$95.00 - $346.75
Current price $95.00
in stock

  Type Sample pan /crucible Suitable for Netzsch Part NO A-NE-2  Volume  25μl Size D7.5*2mm Lid  Without Material Alumina Ceramic ...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$95.00 - $346.75
$95.00 - $346.75
Current price $95.00

80μl Alumina Crucibles D6.7*5mm for Netzsch Ceramic Pans Thermal Analysis Consumables Al2O3 Pan | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$95.00 - $304.00
$95.00 - $304.00
Current price $95.00
in stock

Type Sample pan /crucible Suitable for Netzsch Part NO A-NE-3 for Netzsch Volume μL 80μL Size D6.7*5mm Lid Without Material Alumin...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$95.00 - $304.00
$95.00 - $304.00
Current price $95.00

90μl Alumina Crucibles D6.8*5mm for Netzsch Ceramic Sample Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$114.00 - $741.00
$114.00 - $741.00
Current price $114.00
in stock

Type Sample pan /crucible Suitable for Netzsch Part NO A-NE-8 for Netzsch  Volume μL 90μL    Size D6.8*5mm Lid  Without Material Alu...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$114.00 - $741.00
$114.00 - $741.00
Current price $114.00

160μl Alumina Crucibles D6.4*8mm for Netzsch Ceramic Sample Pans DSC Consumables | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$142.50 - $190.00
$142.50 - $190.00
Current price $142.50
in stock

Type Sample pan /crucible Suitable for Netzsch Part NO A-NE-9 Capacity 160μL Size D6.4*8MM Lid Without Material Alumina Ceramic ...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$142.50 - $190.00
$142.50 - $190.00
Current price $142.50

300μl Ceramic Crucible with Lid for NGB803698/NGB808209 for Netzsch Alumina Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$190.00 - $855.00
$190.00 - $855.00
Current price $190.00
in stock

Type Sample pan /crucible with lid Suitable for Netzsch TG 209 F1 Libra® and TG 209 F3 Tarsus® Part NO A-NE-12 same design as Netzsch NG...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$190.00 - $855.00
$190.00 - $855.00
Current price $190.00

350μl Alumina Sample Pans With Lids for NGB800453/NGB800454 for Netzsch Large Ceramic Crucible | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $285.00
$171.00 - $285.00
Current price $171.00
in stock

Type Sample pan /crucible with lid Suitable for Netzsch TG 209 F1 Libra® and TG 209 F3 Tarsus®  Part NO A-NE-15 same design as Netzsch NGB80...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $285.00
$171.00 - $285.00
Current price $171.00

450μl Alumina Crucibles for Netzsch Thermal Analysis Sample Pans Al2O3 Ceramic Crucible | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $285.00
$171.00 - $285.00
Current price $171.00
in stock

Type Sample pan /crucible Suitable for Netzsch Part NO A-NE-16 for Netzsch Capacity 450μL D8*12MM Lid Without Material Alumina Cer...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $285.00
$171.00 - $285.00
Current price $171.00

1ml Alumina Crucibles Sample Cups for Netzsch Thermal Analysis Sample Pans Al2O3 Ceramic Pan | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$185.25 - $285.00
$185.25 - $285.00
Current price $185.25
in stock

Type Sample pan /crucible Suitable for Netzsch Part No. A-NE-17 Capacity 1ml Lid Without Material Alumina Ceramic Temperature ra...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$185.25 - $285.00
$185.25 - $285.00
Current price $185.25

Alumina Ceramic Disc for Netzsch Size D8*0.64mm Ceramic Plate| NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$85.50 - $209.00
$85.50 - $209.00
Current price $85.50
in stock

  Type Sample pan /crucible Suitable for Netzsch Part NO A-NE-18 Size D8*0.64mm Llid  Without Material Alumina Ceramic  Temperature ...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$85.50 - $209.00
$85.50 - $209.00
Current price $85.50

0.15ml Alumina Crucibles Netzsch GB399147 for Netzsch | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $399.00
$171.00 - $399.00
Current price $171.00
in stock

Type Sample pan /crucible Suitable for Netzsch STA 449 F1/F3 Jupiter and DSC 404 F1/F3 Pegasus  Part NO A-NE-19 same design as Netzsch GB399...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $399.00
$171.00 - $399.00
Current price $171.00

0.15ml Graphite Crucible for Netzsch GB427607 for Netzsch Thermal Analysis Sample Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $346.75
$171.00 - $346.75
Current price $171.00
in stock

Type Sample pan /crucible Suitable for Netzsch  Part NO A-NE-20 same design as GB427607 Capacity 0.15 ml Llid  NO Material Graphite c...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $346.75
$171.00 - $346.75
Current price $171.00

0.2ml Ceramic Sample Crucible for GB445172 for Netzsch Al2O3 Pans NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$256.50 - $646.00
$256.50 - $646.00
Current price $256.50
in stock

Type Sample pan /crucible Suitable for Netzsch DSC 404 F1/F3 Pegasus STA 449 F1/F3/F5 Jupiter Part NO A-NE-21 Capacity 0.2ml Lid  No ...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$256.50 - $646.00
$256.50 - $646.00
Current price $256.50

0.3 Ml Graphite Crucible for Netzsch GB399222 for Netzsch Graphite Sample Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $346.75
$171.00 - $346.75
Current price $171.00
in stock

Type Sample pan /crucible Suitable for Netzsch  DTA Sensor1  of the DSC 404 F1/F3 Pegasus® and for TGA2 , TGA-DTA3  Sensor of the STA 4...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$171.00 - $346.75
$171.00 - $346.75
Current price $171.00

0.3ml Ceramic Sample Crucible for NGB810411 for Netzsch Al2O3 Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$256.50 - $646.00
$256.50 - $646.00
Current price $256.50
in stock

Type Sample pan /crucible Suitable for Netzsch DSC 404 F1/F3 Pegasus, STA 449 F1/F3/F5 Jupiter® Part NO A-NE-22 same design as Netzsch NGB81...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$256.50 - $646.00
$256.50 - $646.00
Current price $256.50

85ul Graphite Crucible for GB399956 for Netzsch Ceramic Sample Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$190.00 - $617.50
$190.00 - $617.50
Current price $190.00
in stock

  Type Sample pan /crucible Suitable for Netzsch STA 449 F1/F3/F5 Jupiter and DSC 404 F1/T3 Pegasus,TG 209 F1 Libra, TG 209 F3 Tarsus P...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$190.00 - $617.50
$190.00 - $617.50
Current price $190.00

Graphite Lid for Volume 85μl Graphite Crucible for GB399957 for Netzsch Graphite Sample Covers | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$152.00 - $308.75
$152.00 - $308.75
Current price $152.00
in stock

Type Graphite Lid Suitable for Netzsch STA 449 F1/F3/F5 Jupiter and DSC 404 F1/T3 Pegasus,TG 209 F1 Libra, TG 209 F3 Tarsus Part NO A-NE-...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$152.00 - $308.75
$152.00 - $308.75
Current price $152.00

85μl Netzsch Aluminum Crucible with Lid for NGB810405/NGB810406/P/N:399.970 for Netzsch AL Sample Pans | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$85.50 - $228.00
$85.50 - $228.00
Current price $85.50
in stock

  Type  Sample pan/crucible with lid Suitable for  Netzsch DSC 204 F1 Phoenix®, DSC 200 F3 Maia®, DSC 3500 Sirius and  DSC 214 Polyma Part N...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$85.50 - $228.00
$85.50 - $228.00
Current price $85.50

Aluminum Crucibles with Lids Size 6.7*4mm for Netzsch OEM AL Sample Pans Thermal Analysis Tool | NEXACULE

NEXACULE
Original price $0.00 - Original price $0.00
Original price $0.00
$114.00 - $209.00
$114.00 - $209.00
Current price $114.00
in stock

  Type Sample pan /crucible with lid Suitable for Netzsch  Part NO A-NA-091-2 Volume Size 6.7*4mm Meterial Aluminum Sealing tool  6.24...

View full details
Original price $0.00 - Original price $0.00
Original price $0.00
$114.00 - $209.00
$114.00 - $209.00
Current price $114.00

Professional Thermal Analysis Consumables for Research & Industry

Thermal analysis is a cornerstone of materials science, quality control, and research across industries including pharmaceuticals, polymers, metals, ceramics, and food science. Our comprehensive selection of thermal analysis consumables supports DSC (Differential Scanning Calorimetry), TGA (Thermogravimetric Analysis), STA (Simultaneous Thermal Analysis), and DMA (Dynamic Mechanical Analysis) applications.

Industry-Leading Compatibility Across All Major Brands

We provide premium-quality consumables compatible with thermal analysis instruments from TA Instruments, PerkinElmer, Netzsch, Mettler Toledo, Shimadzu, Setaram, Hitachi, Rigaku, Linseis, and LECO. Each product is manufactured to exact OEM specifications while offering significant cost savings without compromising analytical precision.

Material Science Excellence

Premium Material Options:

  • Aluminum: Standard choice for DSC analysis (-180°C to 600°C), excellent thermal conductivity
  • Platinum: Ultimate high-temperature performance (up to 1000°C), superior oxidation resistance
  • Ceramic (Alumina): Inert environment analysis, high thermal stability, corrosion resistance
  • Stainless Steel: Medium-temperature applications, mechanical durability
  • Graphite: Specialized high-temperature applications, unique thermal properties
  • Quartz: Ultra-pure analysis, minimal sample interaction

Application-Specific Solutions

Pharmaceutical Industry:

Tzero aluminum pans for precise melting point determination, polymorphism studies, and stability testing. Hermetic sealing options prevent moisture interference in hygroscopic samples.

Polymer Research:

High-volume aluminum crucibles for glass transition temperature measurement, crystallization kinetics, and thermal stability evaluation across diverse polymer matrices.

Metals & Alloys:

Platinum and ceramic crucibles for high-temperature phase transition analysis, oxidation studies, and compositional analysis in metallurgical research.

Food Science:

Specialized aluminum pans for moisture analysis, fat content determination, and thermal processing optimization in food product development.

Quality Assurance & Certification

Every batch undergoes comprehensive quality testing including dimensional verification, material composition analysis, thermal performance validation, and surface finish inspection. Our products meet international standards (ISO, ASTM) and are certified for use in regulated environments including FDA-compliant laboratories.

Thermal Analysis Brand Compatibility Guide

Leading Thermal Analysis Brands Overview:

TA Instruments - Global Market Leader

Specialties: Q-Series DSC, Discovery TGA, Tzero technology
Key Features: Advanced baseline stability, high sensitivity
Popular Models: Q2000, Q5000, DSC25, TGA5500
Sample Requirements: Tzero aluminum pans, platinum crucibles

PerkinElmer - Analytical Excellence

Specialties: STA systems, simultaneous DSC-TGA
Key Features: Integrated analysis, rapid heating rates
Popular Models: STA6000, STA8000, DSC8000, TGA8000
Sample Requirements: Ceramic pans, aluminum crucibles

Netzsch - German Engineering

Specialties: High-temperature analysis, Jupiter STA
Key Features: Exceptional temperature accuracy, robust design
Popular Models: DSC214, STA449, TG209
Sample Requirements: Concavus pans, alumina crucibles

Mettler Toledo - Precision Instruments

Specialties: STAR system, automated sampling
Key Features: Outstanding reproducibility, user-friendly software
Popular Models: DSC3+, TGA2, DSC823e
Sample Requirements: Standard aluminum crucibles, ceramic options

Technical Selection Guide for Optimal Results

Temperature Range Considerations:

Temperature Range Recommended Materials Typical Applications
-180°C to 400°C Aluminum, Stainless Steel Polymer analysis, pharmaceutical studies
400°C to 700°C Ceramic (Alumina), Platinum High-temperature polymers, composites
700°C to 1000°C Platinum, High-purity Alumina Metals, ceramics, catalyst studies
Above 1000°C Platinum, Graphite Refractory materials, advanced ceramics

Atmosphere Compatibility:

  • Inert Atmosphere (N₂, Ar): All materials suitable
  • Oxidizing Atmosphere (Air, O₂): Aluminum, Platinum, Ceramic recommended
  • Reducing Atmosphere (H₂): Platinum, Ceramic, avoid aluminum at high temperatures
  • Corrosive Environments: Platinum, high-purity alumina ceramic

Sample Preparation Best Practices:

  • Optimal sample mass: 5-15mg for DSC, 10-50mg for TGA
  • Ensure uniform sample distribution for consistent heat transfer
  • Consider particle size effects on thermal response
  • Use appropriate lid sealing for hermetic or vented analysis
  • Clean crucibles thoroughly between uses to prevent contamination

Thermal Analysis Consumables FAQ

Q: How do I choose the right crucible material for my thermal analysis?

A: Material selection depends on your analysis requirements:
Aluminum: Best for DSC analysis (-180°C to 600°C), polymer studies, pharmaceutical applications
Platinum: Essential for high-temperature TGA (up to 1000°C), oxidation studies, catalyst analysis
Ceramic (Alumina): Ideal for chemically reactive samples, corrosive materials, high-temperature stability
Stainless Steel: Good for medium-temperature applications requiring mechanical strength

Q: What's the difference between standard and Tzero aluminum pans?

A: Tzero technology from TA Instruments features:
• Enhanced thermal contact between pan and sensor
• Improved baseline flatness and sensitivity
• Better resolution for closely spaced thermal events
• Optimal for precise DSC measurements requiring maximum accuracy

Q: Are your consumables fully compatible with OEM specifications?

A: Yes, our consumables are manufactured to exact OEM dimensional and material specifications. We guarantee:
• Precise dimensional accuracy (±0.01mm tolerance)
• Material composition verification
• Thermal performance equivalence
• Full compatibility with all major thermal analysis instruments

Q: How much can I save compared to OEM consumables?

A: Our compatible consumables typically offer:
• 30-50% cost savings compared to OEM prices
• Bulk purchasing discounts for high-volume users
• Same analytical performance and reliability
• Comprehensive quality certification

Q: What quality certifications do your thermal analysis consumables have?

A: All products undergo rigorous quality control:
• ISO 9001:2015 quality management certification
• Material composition analysis (Certificate of Analysis available)
• Dimensional verification testing
• Thermal performance validation
• Batch traceability for regulatory compliance

Q: Which crucible volume should I choose for my samples?

A: Volume selection guidelines:
20-40μl: Standard for DSC analysis, small sample sizes
90-100μl: TGA applications, larger sample requirements
150-250μl: STA simultaneous analysis, bulk samples
• Consider sample density and thermal conductivity for optimal results

 

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare