Thermal Analysis Consumables
Professional Thermal Analysis Consumables for Research & Industry
Thermal analysis is a cornerstone of materials science, quality control, and research across industries including pharmaceuticals, polymers, metals, ceramics, and food science. Our comprehensive selection of thermal analysis consumables supports DSC (Differential Scanning Calorimetry), TGA (Thermogravimetric Analysis), STA (Simultaneous Thermal Analysis), and DMA (Dynamic Mechanical Analysis) applications.
Industry-Leading Compatibility Across All Major Brands
We provide premium-quality consumables compatible with thermal analysis instruments from TA Instruments, PerkinElmer, Netzsch, Mettler Toledo, Shimadzu, Setaram, Hitachi, Rigaku, Linseis, and LECO. Each product is manufactured to exact OEM specifications while offering significant cost savings without compromising analytical precision.
Material Science Excellence
Premium Material Options:
- Aluminum: Standard choice for DSC analysis (-180°C to 600°C), excellent thermal conductivity
- Platinum: Ultimate high-temperature performance (up to 1000°C), superior oxidation resistance
- Ceramic (Alumina): Inert environment analysis, high thermal stability, corrosion resistance
- Stainless Steel: Medium-temperature applications, mechanical durability
- Graphite: Specialized high-temperature applications, unique thermal properties
- Quartz: Ultra-pure analysis, minimal sample interaction
Application-Specific Solutions
Pharmaceutical Industry:
Tzero aluminum pans for precise melting point determination, polymorphism studies, and stability testing. Hermetic sealing options prevent moisture interference in hygroscopic samples.
Polymer Research:
High-volume aluminum crucibles for glass transition temperature measurement, crystallization kinetics, and thermal stability evaluation across diverse polymer matrices.
Metals & Alloys:
Platinum and ceramic crucibles for high-temperature phase transition analysis, oxidation studies, and compositional analysis in metallurgical research.
Food Science:
Specialized aluminum pans for moisture analysis, fat content determination, and thermal processing optimization in food product development.
Quality Assurance & Certification
Every batch undergoes comprehensive quality testing including dimensional verification, material composition analysis, thermal performance validation, and surface finish inspection. Our products meet international standards (ISO, ASTM) and are certified for use in regulated environments including FDA-compliant laboratories.
Thermal Analysis Brand Compatibility Guide
Leading Thermal Analysis Brands Overview:
TA Instruments - Global Market Leader
Specialties: Q-Series DSC, Discovery TGA, Tzero technology
Key Features: Advanced baseline stability, high sensitivity
Popular Models: Q2000, Q5000, DSC25, TGA5500
Sample Requirements: Tzero aluminum pans, platinum crucibles
PerkinElmer - Analytical Excellence
Specialties: STA systems, simultaneous DSC-TGA
Key Features: Integrated analysis, rapid heating rates
Popular Models: STA6000, STA8000, DSC8000, TGA8000
Sample Requirements: Ceramic pans, aluminum crucibles
Netzsch - German Engineering
Specialties: High-temperature analysis, Jupiter STA
Key Features: Exceptional temperature accuracy, robust design
Popular Models: DSC214, STA449, TG209
Sample Requirements: Concavus pans, alumina crucibles
Mettler Toledo - Precision Instruments
Specialties: STAR system, automated sampling
Key Features: Outstanding reproducibility, user-friendly software
Popular Models: DSC3+, TGA2, DSC823e
Sample Requirements: Standard aluminum crucibles, ceramic options
Technical Selection Guide for Optimal Results
Temperature Range Considerations:
Temperature Range | Recommended Materials | Typical Applications |
---|---|---|
-180°C to 400°C | Aluminum, Stainless Steel | Polymer analysis, pharmaceutical studies |
400°C to 700°C | Ceramic (Alumina), Platinum | High-temperature polymers, composites |
700°C to 1000°C | Platinum, High-purity Alumina | Metals, ceramics, catalyst studies |
Above 1000°C | Platinum, Graphite | Refractory materials, advanced ceramics |
Atmosphere Compatibility:
- Inert Atmosphere (N₂, Ar): All materials suitable
- Oxidizing Atmosphere (Air, O₂): Aluminum, Platinum, Ceramic recommended
- Reducing Atmosphere (H₂): Platinum, Ceramic, avoid aluminum at high temperatures
- Corrosive Environments: Platinum, high-purity alumina ceramic
Sample Preparation Best Practices:
- Optimal sample mass: 5-15mg for DSC, 10-50mg for TGA
- Ensure uniform sample distribution for consistent heat transfer
- Consider particle size effects on thermal response
- Use appropriate lid sealing for hermetic or vented analysis
- Clean crucibles thoroughly between uses to prevent contamination
Thermal Analysis Consumables FAQ
Q: How do I choose the right crucible material for my thermal analysis?
A: Material selection depends on your analysis requirements:
• Aluminum: Best for DSC analysis (-180°C to 600°C), polymer studies, pharmaceutical applications
• Platinum: Essential for high-temperature TGA (up to 1000°C), oxidation studies, catalyst analysis
• Ceramic (Alumina): Ideal for chemically reactive samples, corrosive materials, high-temperature stability
• Stainless Steel: Good for medium-temperature applications requiring mechanical strength
Q: What's the difference between standard and Tzero aluminum pans?
A: Tzero technology from TA Instruments features:
• Enhanced thermal contact between pan and sensor
• Improved baseline flatness and sensitivity
• Better resolution for closely spaced thermal events
• Optimal for precise DSC measurements requiring maximum accuracy
Q: Are your consumables fully compatible with OEM specifications?
A: Yes, our consumables are manufactured to exact OEM dimensional and material specifications. We guarantee:
• Precise dimensional accuracy (±0.01mm tolerance)
• Material composition verification
• Thermal performance equivalence
• Full compatibility with all major thermal analysis instruments
Q: How much can I save compared to OEM consumables?
A: Our compatible consumables typically offer:
• 30-50% cost savings compared to OEM prices
• Bulk purchasing discounts for high-volume users
• Same analytical performance and reliability
• Comprehensive quality certification
Q: What quality certifications do your thermal analysis consumables have?
A: All products undergo rigorous quality control:
• ISO 9001:2015 quality management certification
• Material composition analysis (Certificate of Analysis available)
• Dimensional verification testing
• Thermal performance validation
• Batch traceability for regulatory compliance
Q: Which crucible volume should I choose for my samples?
A: Volume selection guidelines:
• 20-40μl: Standard for DSC analysis, small sample sizes
• 90-100μl: TGA applications, larger sample requirements
• 150-250μl: STA simultaneous analysis, bulk samples
• Consider sample density and thermal conductivity for optimal results
Platinum Macro Pans 201-53843-00 For Shimadzu PT Crucibles | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Shimadzu DSC-60 series, DSC-60 plus series, TGA-50 series, TGA-51 series, DTG-60 series, and DTA-50 ins...
View full details

95μl Alumina Crucibles D7*5*0.6mm For Linseis Al2O3 Ceramic Pan NEXACULE
NEXACULEType Sample pan /crucible Suitable for Linseis Part NO A-L-1 same design as Linseis TGA & DSC Volume μL 95μl Size D7*5*0.6mm Lid ...
View full details165μL Alumina Crucibles Size D6.4*8mm for Linseis Thermal Analysis Sample Pans Al2O3 Ceramic Pan | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Linseis Part NO A-L-2 same design as Linseis TGA &DSC Size D6.4*8mm Lid Without Materia...
View full detailsAlumina Disc D6*2mm for Linseis Thermal Analysis Consumables Ceramic Plate | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Linseis Part NO A-L-3 same design as Linseis TGA & DSC Size D6*2mm Lid Without Material ...
View full details300ul STA Special Shape Alumina Pans for Linseis Al2O3 Crucibles DSC Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Linseis Part NO A-L-4 same design as Linseis TGA & DSC Size 300μl D7*17.4*0.5mm Lid Withou...
View full details3ml Alumina Ceramic Crucibles For Linseis Thermal Analysis Consumables Al2O3 Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Linseis Part NO A-L-5 same design as Linseis TGA & DSC Size 3ml D17*30*0.5mm Lid Without ...
View full details30μl Alumina Crucibles Size D5*3.5mm for Setaram DSC TGA Instrument Al2O3 Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-1 same design as Setaram TGA &DSC Volume and Size 30μl D5*5.3mm Lid ...
View full details50μl Alumina Crucibles D5*4MM For Setaram DSC TGA Instrument Ceramic Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-2 same design as Setaram TGA &DSC Volume μL 50μl Lid Without Mater...
View full details95μl Alumina Crucible Size D8*3mm for SETARAM Ceramic Sample Pans Thermal Analyzer Crucibles | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-3 same design as Setaram TGA &DSC Volume μL 95μl D8*3MM Lid Without ...
View full details100μl Alumina Crucible D5*8mm for SETARAM LABSYS DSC TGA Ceramic Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-4 Setaram TGA &DSC Volume μL 100μl D5*8MM Lid Without Material Al...
View full details100μl Zirconia Crucible D5*8mm for SETARAM LABSYS Ceramic Sample Pans DSC Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-5 same design as Setaram TGA &DSC Volume μL 100μl Lid Without Materi...
View full details160μl Alumina Crucibles Size D8*6mm with Hole for Setaram Ceramic Sample Pans DSC Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-6 same design as Setaram TGA &DSC Volume 160μl Lid Without Materi...
View full detailsAlumina Crucibles Size D5*10mm and Size D5*4.5mm for Setaram Ceramic Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible Set Suitable for Setaram Part NO A-ST-8-1 same design as Setaram TGA &DSC Volume μL include 2pcs crucible:...
View full details400μl Alumina Crucibles for SETARAM LABSYS Ceramic Sample Pans DSC Consumables | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-10 same design as Setaram TGA &DSC Volume μL 400μl D8*12MM Lid Withou...
View full details100μl Alumina Crucibles Special Shape Size D5*10mm for SETARAM Ceramic Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Setaram Part NO A-ST-11 same design as Setaram TGA &DSC Volume μL 100μl Li...
View full detailsAluminum Sample Pans With Covers Size D5*2.5mm for Setaram AL Crucibles with Lid | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Setaram Part NO A-ST-12 Size D5*2.5 Lid With Material Aluminum Temperature range -1...
View full detailsSmall TGA Ceramic Crucible 16ml for LECO 529-042 AR9042 TGA Accessories | NEXACULE
NEXACULEVolume: 16ml Lid No/ with lid 529-043 both can be choose Part No. A-MY-17 16CC equivalent to LECO 529-042 Compatible Instruments Leco...
View full detailsSmall Crucible Cover for LECO 529-043 Ceramic Covers TGA Lid | NEXACULE
NEXACULEVolume: for 16ml Crucible Consumables Leco:529-042 Part No. Lid for samll tga crucible ,A-MY-18 equivalent to LECO 529-043 Compatible ...
View full detailsAluminum Sample Pans with Lids D5*8mm for SETARAM AL Crucibles DSC Consumables | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Setaram Part NO A-ST-14 same design as Setaram TGA &DSC Volume 渭L D5*8mm Lid Wi...
View full detailsPlatinum Sample Pans with Covers Size D5*8mm for SETARAM Pt Crucibles | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Setaram Part NO A-ST-15 same design as Setaram TGA & DSC Size D5*8mm Lid With ...
View full details30μl Disposable High Pressure Crucible With Lid and Seal Gold Plated for Setaram | NEXACULE
NEXACULEType High pressure crucible Suitable for Setaram Part NO. A-ST-16 Capacity 30μl Lid With Seal With Material Stainless steel Matchi...
View full details30μl Disposable High Pressure Crucible With Lid and Seal Stainless Steel for Setaram | NEXACULE
NEXACULEType High pressure crucible Suitable for Setaram Part NO. A-ST-17 Capacity 30μl Lid With Seal With Material Stainless steel If need...
View full details30μl Alumina Crucibles Small with Lid for ME-51140843 for Mettler Toledo/Mettler | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Mettler TGA/sample robot Part NO A-M-01 same design as ME-51140843 Volume μL 30 μL Li...
View full details50μl Alumina Crucibles With Lid Suit For Mettler Toledo/Mettler Platinum Crucible Al2O3 Sample Pans | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Mettler 70ul Platinum crucible ME-51119654 Part NO A-M-03/A-MA-002-4 Volume μL 50 μL Lid With ...
View full detailsProfessional Thermal Analysis Consumables for Research & Industry
Thermal analysis is a cornerstone of materials science, quality control, and research across industries including pharmaceuticals, polymers, metals, ceramics, and food science. Our comprehensive selection of thermal analysis consumables supports DSC (Differential Scanning Calorimetry), TGA (Thermogravimetric Analysis), STA (Simultaneous Thermal Analysis), and DMA (Dynamic Mechanical Analysis) applications.
Industry-Leading Compatibility Across All Major Brands
We provide premium-quality consumables compatible with thermal analysis instruments from TA Instruments, PerkinElmer, Netzsch, Mettler Toledo, Shimadzu, Setaram, Hitachi, Rigaku, Linseis, and LECO. Each product is manufactured to exact OEM specifications while offering significant cost savings without compromising analytical precision.
Material Science Excellence
Premium Material Options:
- Aluminum: Standard choice for DSC analysis (-180°C to 600°C), excellent thermal conductivity
- Platinum: Ultimate high-temperature performance (up to 1000°C), superior oxidation resistance
- Ceramic (Alumina): Inert environment analysis, high thermal stability, corrosion resistance
- Stainless Steel: Medium-temperature applications, mechanical durability
- Graphite: Specialized high-temperature applications, unique thermal properties
- Quartz: Ultra-pure analysis, minimal sample interaction
Application-Specific Solutions
Pharmaceutical Industry:
Tzero aluminum pans for precise melting point determination, polymorphism studies, and stability testing. Hermetic sealing options prevent moisture interference in hygroscopic samples.
Polymer Research:
High-volume aluminum crucibles for glass transition temperature measurement, crystallization kinetics, and thermal stability evaluation across diverse polymer matrices.
Metals & Alloys:
Platinum and ceramic crucibles for high-temperature phase transition analysis, oxidation studies, and compositional analysis in metallurgical research.
Food Science:
Specialized aluminum pans for moisture analysis, fat content determination, and thermal processing optimization in food product development.
Quality Assurance & Certification
Every batch undergoes comprehensive quality testing including dimensional verification, material composition analysis, thermal performance validation, and surface finish inspection. Our products meet international standards (ISO, ASTM) and are certified for use in regulated environments including FDA-compliant laboratories.
Thermal Analysis Brand Compatibility Guide
Leading Thermal Analysis Brands Overview:
TA Instruments - Global Market Leader
Specialties: Q-Series DSC, Discovery TGA, Tzero technology
Key Features: Advanced baseline stability, high sensitivity
Popular Models: Q2000, Q5000, DSC25, TGA5500
Sample Requirements: Tzero aluminum pans, platinum crucibles
PerkinElmer - Analytical Excellence
Specialties: STA systems, simultaneous DSC-TGA
Key Features: Integrated analysis, rapid heating rates
Popular Models: STA6000, STA8000, DSC8000, TGA8000
Sample Requirements: Ceramic pans, aluminum crucibles
Netzsch - German Engineering
Specialties: High-temperature analysis, Jupiter STA
Key Features: Exceptional temperature accuracy, robust design
Popular Models: DSC214, STA449, TG209
Sample Requirements: Concavus pans, alumina crucibles
Mettler Toledo - Precision Instruments
Specialties: STAR system, automated sampling
Key Features: Outstanding reproducibility, user-friendly software
Popular Models: DSC3+, TGA2, DSC823e
Sample Requirements: Standard aluminum crucibles, ceramic options
Technical Selection Guide for Optimal Results
Temperature Range Considerations:
Temperature Range | Recommended Materials | Typical Applications |
---|---|---|
-180°C to 400°C | Aluminum, Stainless Steel | Polymer analysis, pharmaceutical studies |
400°C to 700°C | Ceramic (Alumina), Platinum | High-temperature polymers, composites |
700°C to 1000°C | Platinum, High-purity Alumina | Metals, ceramics, catalyst studies |
Above 1000°C | Platinum, Graphite | Refractory materials, advanced ceramics |
Atmosphere Compatibility:
- Inert Atmosphere (N₂, Ar): All materials suitable
- Oxidizing Atmosphere (Air, O₂): Aluminum, Platinum, Ceramic recommended
- Reducing Atmosphere (H₂): Platinum, Ceramic, avoid aluminum at high temperatures
- Corrosive Environments: Platinum, high-purity alumina ceramic
Sample Preparation Best Practices:
- Optimal sample mass: 5-15mg for DSC, 10-50mg for TGA
- Ensure uniform sample distribution for consistent heat transfer
- Consider particle size effects on thermal response
- Use appropriate lid sealing for hermetic or vented analysis
- Clean crucibles thoroughly between uses to prevent contamination
Thermal Analysis Consumables FAQ
Q: How do I choose the right crucible material for my thermal analysis?
A: Material selection depends on your analysis requirements:
• Aluminum: Best for DSC analysis (-180°C to 600°C), polymer studies, pharmaceutical applications
• Platinum: Essential for high-temperature TGA (up to 1000°C), oxidation studies, catalyst analysis
• Ceramic (Alumina): Ideal for chemically reactive samples, corrosive materials, high-temperature stability
• Stainless Steel: Good for medium-temperature applications requiring mechanical strength
Q: What's the difference between standard and Tzero aluminum pans?
A: Tzero technology from TA Instruments features:
• Enhanced thermal contact between pan and sensor
• Improved baseline flatness and sensitivity
• Better resolution for closely spaced thermal events
• Optimal for precise DSC measurements requiring maximum accuracy
Q: Are your consumables fully compatible with OEM specifications?
A: Yes, our consumables are manufactured to exact OEM dimensional and material specifications. We guarantee:
• Precise dimensional accuracy (±0.01mm tolerance)
• Material composition verification
• Thermal performance equivalence
• Full compatibility with all major thermal analysis instruments
Q: How much can I save compared to OEM consumables?
A: Our compatible consumables typically offer:
• 30-50% cost savings compared to OEM prices
• Bulk purchasing discounts for high-volume users
• Same analytical performance and reliability
• Comprehensive quality certification
Q: What quality certifications do your thermal analysis consumables have?
A: All products undergo rigorous quality control:
• ISO 9001:2015 quality management certification
• Material composition analysis (Certificate of Analysis available)
• Dimensional verification testing
• Thermal performance validation
• Batch traceability for regulatory compliance
Q: Which crucible volume should I choose for my samples?
A: Volume selection guidelines:
• 20-40μl: Standard for DSC analysis, small sample sizes
• 90-100μl: TGA applications, larger sample requirements
• 150-250μl: STA simultaneous analysis, bulk samples
• Consider sample density and thermal conductivity for optimal results