Thermal Analysis Consumables with Netzsch | DSC/TGA/STA Crucibles & Pans
Professional Thermal Analysis Consumables for Netzsch Systems
Our precision-engineered thermal analysis consumables are designed for seamless compatibility with Netzsch DSC, TGA, and STA instruments. These high-performance alternatives deliver the same reliability and accuracy as original equipment at competitive prices, making them ideal for research laboratories, quality control, and industrial applications.
Why Choose Our Netzsch-Compatible Consumables?
- Perfect Compatibility: Engineered to exact specifications for DSC 204, DSC 3500, STA 449, TGA 209 series
- Premium Materials: High-purity alumina ceramic, platinum, graphite, and aluminum options
- Cost Savings: Save up to 50% compared to original equipment pricing
- Quality Assured: Every batch tested for dimensional accuracy and thermal performance
- Ready Stock: Fast shipping with most items available for immediate delivery
Compatible Netzsch Instrument Series
DSC Series: DSC 204 F1 Phoenix, DSC 200 F3 Maia, DSC 3500 Sirius, DSC 214 Polyma
STA Series: STA 449 F1/F3/F5 Jupiter, STA 2500 Regulus
TGA Series: TG 209 F1 Libra, TG 209 F3 Tarsus
Special Applications: High-pressure, high-temperature, and corrosive sample analysis
Material Specifications for Netzsch Systems
Material | Volume Range | Max Temperature | Compatible Models | Best Applications |
---|---|---|---|---|
Alumina Ceramic | 25μl - 3.4ml | 1600°C | DSC 204, STA 449, TGA 209 | High-temp, corrosive samples |
Aluminum | 25-40μl | 600°C | DSC 204, DSC 3500 | Standard DSC analysis |
Platinum | 30-85μl | 1500°C | All DSC/STA models | Trace analysis, research |
Graphite | 85μl - 0.3ml | 2000°C | STA 449, DSC 404 | Extreme temperature studies |
Application Guidelines for Netzsch Systems
DSC Applications (DSC 204, DSC 3500 Series)
- Polymer Analysis: Use 25-40μl aluminum crucibles for melting point and glass transitions
- Pharmaceutical Testing: Alumina crucibles for decomposition studies up to 1600°C
- Materials Research: Platinum crucibles for contamination-free analysis
STA Applications (STA 449 Jupiter Series)
- Simultaneous TGA-DSC: 85μl alumina crucibles with lids for controlled atmosphere
- Catalysis Studies: Large volume crucibles (300-450μl) for sufficient sample loading
- High-Temperature Analysis: Graphite crucibles for extreme conditions
TGA Applications (TG 209 Series)
- Decomposition Studies: Open crucibles for gas evolution analysis
- Oxidation Resistance: Alumina crucibles for corrosive atmosphere testing
- Sample Preparation: Multiple volume options for different sample sizes
Technical Support & Quality Assurance
Dimensional Accuracy
All crucibles manufactured to ±0.05mm tolerance to ensure perfect fit in Netzsch sample holders and furnaces.
Material Purity
High-purity materials (>99.5% Al₂O₃, 99.9% Pt) to minimize sample contamination and ensure accurate thermal measurements.
Thermal Performance
Each batch validated for thermal conductivity and stability to match Netzsch instrument calibration requirements.
Part Number Cross-Reference
Complete compatibility database available for all Netzsch part numbers including GB, NGB, and HTP series consumables.
Frequently Asked Questions
Are these consumables compatible with all Netzsch instrument generations?
Yes, our consumables are designed to be compatible with both current and legacy Netzsch instruments including F1, F3, and F5 generation systems.
How do I identify the correct crucible for my Netzsch instrument?
Check your instrument manual for the recommended part number (GB, NGB, or HTP series), or contact our technical support team with your instrument model for guidance.
What's the difference between alumina and platinum crucibles?
Alumina offers excellent chemical resistance and high-temperature capability at lower cost. Platinum provides superior inertness for trace analysis and research applications requiring contamination-free results.
*All Netzsch part numbers and instrument models mentioned are for compatibility reference only. We are an independent supplier and not affiliated with Netzsch. All trademarks belong to their respective owners.
TG DSC DTA Sample Carriers Type S(PtRh) Sensors for Netzsch | NEXACULE
NEXACULEItem Sample carrier/Sensor Material Alumina, Platinum Part No. A-NA-409PC Temperature Range Room temperature to 1500℃ Sample Carrier...
View full detailsStandard Sample Carrier/Sample Sensor DSC-TG Thermocouple Type P for Netzsch | NEXACULE
NEXACULEItem Sample carrier/Sensor Material Alumina, Platinum, Part No. A-NA-209 Temperature Range Room temperature to 1000℃ Sample Carriers...
View full details5ml Alumina Ceramic Crucibles for NGB809163 for TGA Sample Carrier Of Netzsch Thermal Analysis Sample Pans | NEXACULE
NEXACULEType Alumina crucibles Suitable for Netzsch STA 449 F1/F3/F5 Jupiter®, STA 449 F3 Nevio Part No. A-NA-088-01 same design as Netzsch NGB8...
View full details4.2ml Ceramic Crucible for TGA Sample Carrier Of Netzsch DSC Consumables Alumina Pan | NEXACULE
NEXACULEType Alumina crucibles Suitable for Netzsch STA 449 F1/F3/F5 Jupiter®, STA 449 F3 Nevio Part No. A-NA-088-02 Netzsch Capacity 4.2ml Ma...
View full detailsDSC Cell Cleaning Brush/Furnace Cleaning Brush Kit for TA 910824.001 for TA Instruments/TA | NEXACULE
NEXACULEDescription: Item:Furnace Brush Material:Fiberglass Suitable for:PerkinElmer/TA910824.001 /Netzsch/Mettler Toledo/Hitachi Thermal Analyzers Part N...
View full details85μl Zirconia Crucible With Lid Netzsch GB397053 /GB397052 for Netzsch Thermal Analysis Sample Pans | NEXACULE
NEXACULEItem Crucible with lid Suitable for Netzsch Part NO A-NA-072-2 Same Design As Netzsch GB397053 /GB397052 Volume μL 85 ul Max Temp 1...
View full details85μl Nickel Thermal Analyzer Sample Pan with lid for Netzsch DSC Pan | NEXACULE
NEXACULEType Crucible with lid Suitable for Netzsch Part NO A-NE-44 Volume μL 85 ul Lid With Material Nickel Brand NEXACULE Original M...
View full details30/40μl Standard aluminum sample pan with lid for Netzsch NGB817525/NGB817526 DSC Sample Pans Aluminum thermal pans NEXACULE
NEXACULEType crucible with lid Suitable for DSC, STA Part NO A-NM-093-8 Same Design As Netzsch NGB817525/NGB817526 and DSC21400A66.010.00 V...
View full details85μl Sapphire crucible with lid same size as Netzsch GB399972 &GB399973 for Netzsch Sapphire Pans | NEXACULE
NEXACULEType Crucible with lid Suitable for Netzsch Part NO A-NM-095 same size as Netzsch GB399972 &GB399973 Volume μL 85 ul Lid with Mat...
View full details85μl Platinum Sample Pan with Lid Same Size As Netzsch GB399205/GB399860 for Netzsch Platinum Crucibles | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part NO A-NB-095-4 same design as Netzsch GB399205/GB399860 Volume 85μl ...
View full detailsProfessional Thermal Analysis Consumables for Netzsch Systems
Our precision-engineered thermal analysis consumables are designed for seamless compatibility with Netzsch DSC, TGA, and STA instruments. These high-performance alternatives deliver the same reliability and accuracy as original equipment at competitive prices, making them ideal for research laboratories, quality control, and industrial applications.
Why Choose Our Netzsch-Compatible Consumables?
- Perfect Compatibility: Engineered to exact specifications for DSC 204, DSC 3500, STA 449, TGA 209 series
- Premium Materials: High-purity alumina ceramic, platinum, graphite, and aluminum options
- Cost Savings: Save up to 50% compared to original equipment pricing
- Quality Assured: Every batch tested for dimensional accuracy and thermal performance
- Ready Stock: Fast shipping with most items available for immediate delivery
Compatible Netzsch Instrument Series
DSC Series: DSC 204 F1 Phoenix, DSC 200 F3 Maia, DSC 3500 Sirius, DSC 214 Polyma
STA Series: STA 449 F1/F3/F5 Jupiter, STA 2500 Regulus
TGA Series: TG 209 F1 Libra, TG 209 F3 Tarsus
Special Applications: High-pressure, high-temperature, and corrosive sample analysis
Material Specifications for Netzsch Systems
Material | Volume Range | Max Temperature | Compatible Models | Best Applications |
---|---|---|---|---|
Alumina Ceramic | 25μl - 3.4ml | 1600°C | DSC 204, STA 449, TGA 209 | High-temp, corrosive samples |
Aluminum | 25-40μl | 600°C | DSC 204, DSC 3500 | Standard DSC analysis |
Platinum | 30-85μl | 1500°C | All DSC/STA models | Trace analysis, research |
Graphite | 85μl - 0.3ml | 2000°C | STA 449, DSC 404 | Extreme temperature studies |
Application Guidelines for Netzsch Systems
DSC Applications (DSC 204, DSC 3500 Series)
- Polymer Analysis: Use 25-40μl aluminum crucibles for melting point and glass transitions
- Pharmaceutical Testing: Alumina crucibles for decomposition studies up to 1600°C
- Materials Research: Platinum crucibles for contamination-free analysis
STA Applications (STA 449 Jupiter Series)
- Simultaneous TGA-DSC: 85μl alumina crucibles with lids for controlled atmosphere
- Catalysis Studies: Large volume crucibles (300-450μl) for sufficient sample loading
- High-Temperature Analysis: Graphite crucibles for extreme conditions
TGA Applications (TG 209 Series)
- Decomposition Studies: Open crucibles for gas evolution analysis
- Oxidation Resistance: Alumina crucibles for corrosive atmosphere testing
- Sample Preparation: Multiple volume options for different sample sizes
Technical Support & Quality Assurance
Dimensional Accuracy
All crucibles manufactured to ±0.05mm tolerance to ensure perfect fit in Netzsch sample holders and furnaces.
Material Purity
High-purity materials (>99.5% Al₂O₃, 99.9% Pt) to minimize sample contamination and ensure accurate thermal measurements.
Thermal Performance
Each batch validated for thermal conductivity and stability to match Netzsch instrument calibration requirements.
Part Number Cross-Reference
Complete compatibility database available for all Netzsch part numbers including GB, NGB, and HTP series consumables.
Frequently Asked Questions
Are these consumables compatible with all Netzsch instrument generations?
Yes, our consumables are designed to be compatible with both current and legacy Netzsch instruments including F1, F3, and F5 generation systems.
How do I identify the correct crucible for my Netzsch instrument?
Check your instrument manual for the recommended part number (GB, NGB, or HTP series), or contact our technical support team with your instrument model for guidance.
What's the difference between alumina and platinum crucibles?
Alumina offers excellent chemical resistance and high-temperature capability at lower cost. Platinum provides superior inertness for trace analysis and research applications requiring contamination-free results.
*All Netzsch part numbers and instrument models mentioned are for compatibility reference only. We are an independent supplier and not affiliated with Netzsch. All trademarks belong to their respective owners.