Thermal Analysis Consumables with Netzsch | DSC/TGA/STA Crucibles & Pans
Professional Thermal Analysis Consumables for Netzsch Systems
Our precision-engineered thermal analysis consumables are designed for seamless compatibility with Netzsch DSC, TGA, and STA instruments. These high-performance alternatives deliver the same reliability and accuracy as original equipment at competitive prices, making them ideal for research laboratories, quality control, and industrial applications.
Why Choose Our Netzsch-Compatible Consumables?
- Perfect Compatibility: Engineered to exact specifications for DSC 204, DSC 3500, STA 449, TGA 209 series
- Premium Materials: High-purity alumina ceramic, platinum, graphite, and aluminum options
- Cost Savings: Save up to 50% compared to original equipment pricing
- Quality Assured: Every batch tested for dimensional accuracy and thermal performance
- Ready Stock: Fast shipping with most items available for immediate delivery
Compatible Netzsch Instrument Series
DSC Series: DSC 204 F1 Phoenix, DSC 200 F3 Maia, DSC 3500 Sirius, DSC 214 Polyma
STA Series: STA 449 F1/F3/F5 Jupiter, STA 2500 Regulus
TGA Series: TG 209 F1 Libra, TG 209 F3 Tarsus
Special Applications: High-pressure, high-temperature, and corrosive sample analysis
Material Specifications for Netzsch Systems
Material | Volume Range | Max Temperature | Compatible Models | Best Applications |
---|---|---|---|---|
Alumina Ceramic | 25μl - 3.4ml | 1600°C | DSC 204, STA 449, TGA 209 | High-temp, corrosive samples |
Aluminum | 25-40μl | 600°C | DSC 204, DSC 3500 | Standard DSC analysis |
Platinum | 30-85μl | 1500°C | All DSC/STA models | Trace analysis, research |
Graphite | 85μl - 0.3ml | 2000°C | STA 449, DSC 404 | Extreme temperature studies |
Application Guidelines for Netzsch Systems
DSC Applications (DSC 204, DSC 3500 Series)
- Polymer Analysis: Use 25-40μl aluminum crucibles for melting point and glass transitions
- Pharmaceutical Testing: Alumina crucibles for decomposition studies up to 1600°C
- Materials Research: Platinum crucibles for contamination-free analysis
STA Applications (STA 449 Jupiter Series)
- Simultaneous TGA-DSC: 85μl alumina crucibles with lids for controlled atmosphere
- Catalysis Studies: Large volume crucibles (300-450μl) for sufficient sample loading
- High-Temperature Analysis: Graphite crucibles for extreme conditions
TGA Applications (TG 209 Series)
- Decomposition Studies: Open crucibles for gas evolution analysis
- Oxidation Resistance: Alumina crucibles for corrosive atmosphere testing
- Sample Preparation: Multiple volume options for different sample sizes
Technical Support & Quality Assurance
Dimensional Accuracy
All crucibles manufactured to ±0.05mm tolerance to ensure perfect fit in Netzsch sample holders and furnaces.
Material Purity
High-purity materials (>99.5% Al₂O₃, 99.9% Pt) to minimize sample contamination and ensure accurate thermal measurements.
Thermal Performance
Each batch validated for thermal conductivity and stability to match Netzsch instrument calibration requirements.
Part Number Cross-Reference
Complete compatibility database available for all Netzsch part numbers including GB, NGB, and HTP series consumables.
Frequently Asked Questions
Are these consumables compatible with all Netzsch instrument generations?
Yes, our consumables are designed to be compatible with both current and legacy Netzsch instruments including F1, F3, and F5 generation systems.
How do I identify the correct crucible for my Netzsch instrument?
Check your instrument manual for the recommended part number (GB, NGB, or HTP series), or contact our technical support team with your instrument model for guidance.
What's the difference between alumina and platinum crucibles?
Alumina offers excellent chemical resistance and high-temperature capability at lower cost. Platinum provides superior inertness for trace analysis and research applications requiring contamination-free results.
*All Netzsch part numbers and instrument models mentioned are for compatibility reference only. We are an independent supplier and not affiliated with Netzsch. All trademarks belong to their respective owners.
85μl Netzsch Aluminum Crucible with Lid for NGB810405/NGB810406/P/N:399.970 for Netzsch AL Sample Pans | NEXACULE
NEXACULEType Sample pan/crucible with lid Suitable for Netzsch DSC 204 F1 Phoenix®, DSC 200 F3 Maia®, DSC 3500 Sirius and DSC 214 Polyma Part N...
View full detailsAluminum Crucibles with Lids Size 6.7*4mm for Netzsch OEM AL Sample Pans Thermal Analysis Tool | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part NO A-NA-091-2 Volume Size 6.7*4mm Meterial Aluminum Sealing tool 6.24...
View full details35μl Aluminum Crucible with Lid for Netzsch NGB810419/NGB8104 for Netzsch Aluminium Sample Pans | NEXACULE
NEXACULEType Sample pan/crucible with lid Suitable for Netzsch Part NO A-NE-33 same design as Netzsch NGB810419/NGB810420 Volume 35μl Lid ...
View full details30/40μl Standard Aluminum Concavus Sample Pan/Lid Set for Netzsch NGB814672/NGB814673 for Netzsch Aluminium Crucible | NEXACULE
NEXACULEType Sample pan/crucible Suitable for STA 449 F1 & F3 DSC 204 F1 Phoenix® DSC 200 F3 Maia® DSC 3500 Sirius DSC 214 Polyma Part...
View full detailsSealing Press/Tools for Netzsch 6.240.10-80.0.00A for Sample Pans | NEXACULE
NEXACULEType Sample pan/crucible sealing press Suitable for Netzsch Part NO A-NE-38 equivalent to 6.240.10-80.0.00A Set Include one Crucibl...
View full details190μl Platinum Sample Pan With Lid Same Size As NGB801556/GB399860 for Netzsch PT Crucibles | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch DSC 204 F1 Phoenix®, DSC 200 F3 Maia®, DSC 3500 Sirius and DSC 214 Polyma, TG 209 ...
View full details75ul PT Sample Pans with Lids Size D7*2.4mm for Netzsch Platinum Crucible | NEXACULE
NEXACULEType Sample pan /crucible with lid Part NO A-NE-42 for Netzsch Capacity 75ul Lid With Material PT/RH Platinum Stocking time 1-7 w...
View full details85μl Copper Crucibles with Lids Size D6.8*4mm for Netzsch Copper Sample Pan | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part NO A-NE-43 Capacity 85ul Lid With Pin No Material Copper Stocking...
View full details27μl Reusable High Pressure Crucible with Lid and Seal for Netzsch 6.239.2-92.3.00 | NEXACULE
NEXACULEType High pressure crucible(with lid/seal) Suitable for Netzsch Part NO A-NE-45 same design as Netzsch 6.239.2-93.3.00 Matching Pan ki...
View full details100μl Reusable High Pressure Sample Crucible with Lid and Seal for Netzsch 6.239.2-93.4.00 | NEXACULE
NEXACULEType High pressure crucible(with lid/seal) Suitable for Netzsch Part NO A-NE-46 one crucible with lid with one seal ,equivalent to Netzsch...
View full details100μl Reusable High Pressure Sample Crucible with Lid/Seal Gold Plated for Netzsch 6.239.2-92.8.00 | NEXACULE
NEXACULEType High pressure crucible(with lid/seal) Suitable for Netzsch Matching Pan Kit 1.High Pressure Pan Kit NETZSCH for Reusable High pressur...
View full details27μl Reusable High Pressure Crucible with Lid/Seal Gold Plated for Netzsch 6.239.2-92.3.00 | NEXACULE
NEXACULEType High pressure crucible(with lid/seal) Suitable for Netzsch Part NO. A-NE-48 equivalent to Netzsch 6.239.2-92.3.00 Matching pan kit...
View full detailsStandard High Pressure Pan Kit for Reusable High Pressure Capsules Suit for Netzsch 27ul/100ul Reusable High Pressure Crucible | NEXACULE
NEXACULEType Pressure Pan Kit Suitable for NETZSCH and 27ul /100ul Reusable High pressure crucible ( gold plated or not) Part No. A-NE-49 Capaci...
View full detailsOEM Reusable High Pressure Crucible Sealing Tool For NETZSCH Suit For 27ul /100ul Reusable High Pressure Crucible Gold Plated Or Not | NEXACULE
NEXACULEType Sample pan/crucible sealing press Suitable for NETZSCH and for 27ul /100ul Reusable High pressure crucible ( gold plated or not) ...
View full details85μl Graphite Crucibles with Lids for Netzsch GB399956 /GB399957 for Netzsch | NEXACULE
NEXACULEType Crucible with lid Suitable for Netzsch Part NO A-NASM-071 same design as GB399956/GB399957 Volume μL 85ul Lid With Material G...
View full details150μl PT Platinum Crucible with Lids D6.7*5MM for Netzsch Thermal Analysis Sample Pan | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part NO A-NB-096 Volume 150μl Size 6.7*5MM Lid With Material PT platinum 9...
View full details80μl PT/Platinum Crucible with Lids D6.7*3MM for Netzsch DSC Thermal Analysis Crucibles | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part No. A-NA-093 Volume 80μl Size 6.7*3MM Lid With Material PT/Platinum 9...
View full details

40μl Alumina Crucible with Lid for Netzsch Al2O3 Ceramic Pans | NEXACULE
NEXACULEDescription: Type Sample pan/crucible with lid Suitable for Netzsch DSC instruments Part NO A-NA-090-5 Material Al2O3, 99.7% Volume μL 4...
View full details100μl Alumina Crucible with Lid D9*H8MM for Netzsch Ceramic Crucibles | NEXACULE
NEXACULEType Sample pan /crucible with lid Suitable for Netzsch Part No. A-NA-094-1 Capacity 100μL D9MM*H8MM Lid With lid Material Alumina...
View full detailsAlumina Ceramic Washer NGB811071 for Netzsch Thermal Analysis Consumables | NEXACULE
NEXACULEDescription: Type Sample pan /crucible Suitable for Netzsch Part NO A-NA-095 same design as Netzsch NGB811071 Size D6.8mm Lid Without ...
View full detailsHigh Pressure Capsule Seals Gold Plated Seals for 100μl Sample Crucible for Netzsch Thermal Analysis Consumables | NEXACULE
NEXACULEType seal Suitable for Netzsch Part No. A-NB-099-1 Matching pan kit 1.High Pressure Pan Kit NETZSCH for Reusable High pressure capsul...
View full details45μL Alumina Crucible Netzsch GB800153 for Netzsch Al2O3 Ceramic Crucible | NEXACULE
NEXACULEType Sample pan /crucible Suitable for Netzsch Part NO A-NA-096 Same Design As Netzsch GB800153 Size 45ul Lid Without Material Alu...
View full details85μl Pt/Rh 80/20 Sample Pan With Lid Netzsch GB399205/GB399860 for Netzsch Platinum Crucibles | NEXACULE
NEXACULEDescription: Type Sample pan /crucible with lid Suitable for Netzsch DSC 204 F1 Phoenix®, DSC 200 F3 Maia® DSC 3500 Sirius and DSC 214 P...
View full details

Standard Sample Carriers Type S(PtRh)for Netzsch HTP40000A69.000-00 | NEXACULE
NEXACULEStandard Sample Carriers Type S (PtRh) for Netzsch STA 449 Series Product Overview Professional-grade sample carriers designed specifically for Net...
View full detailsProfessional Thermal Analysis Consumables for Netzsch Systems
Our precision-engineered thermal analysis consumables are designed for seamless compatibility with Netzsch DSC, TGA, and STA instruments. These high-performance alternatives deliver the same reliability and accuracy as original equipment at competitive prices, making them ideal for research laboratories, quality control, and industrial applications.
Why Choose Our Netzsch-Compatible Consumables?
- Perfect Compatibility: Engineered to exact specifications for DSC 204, DSC 3500, STA 449, TGA 209 series
- Premium Materials: High-purity alumina ceramic, platinum, graphite, and aluminum options
- Cost Savings: Save up to 50% compared to original equipment pricing
- Quality Assured: Every batch tested for dimensional accuracy and thermal performance
- Ready Stock: Fast shipping with most items available for immediate delivery
Compatible Netzsch Instrument Series
DSC Series: DSC 204 F1 Phoenix, DSC 200 F3 Maia, DSC 3500 Sirius, DSC 214 Polyma
STA Series: STA 449 F1/F3/F5 Jupiter, STA 2500 Regulus
TGA Series: TG 209 F1 Libra, TG 209 F3 Tarsus
Special Applications: High-pressure, high-temperature, and corrosive sample analysis
Material Specifications for Netzsch Systems
Material | Volume Range | Max Temperature | Compatible Models | Best Applications |
---|---|---|---|---|
Alumina Ceramic | 25μl - 3.4ml | 1600°C | DSC 204, STA 449, TGA 209 | High-temp, corrosive samples |
Aluminum | 25-40μl | 600°C | DSC 204, DSC 3500 | Standard DSC analysis |
Platinum | 30-85μl | 1500°C | All DSC/STA models | Trace analysis, research |
Graphite | 85μl - 0.3ml | 2000°C | STA 449, DSC 404 | Extreme temperature studies |
Application Guidelines for Netzsch Systems
DSC Applications (DSC 204, DSC 3500 Series)
- Polymer Analysis: Use 25-40μl aluminum crucibles for melting point and glass transitions
- Pharmaceutical Testing: Alumina crucibles for decomposition studies up to 1600°C
- Materials Research: Platinum crucibles for contamination-free analysis
STA Applications (STA 449 Jupiter Series)
- Simultaneous TGA-DSC: 85μl alumina crucibles with lids for controlled atmosphere
- Catalysis Studies: Large volume crucibles (300-450μl) for sufficient sample loading
- High-Temperature Analysis: Graphite crucibles for extreme conditions
TGA Applications (TG 209 Series)
- Decomposition Studies: Open crucibles for gas evolution analysis
- Oxidation Resistance: Alumina crucibles for corrosive atmosphere testing
- Sample Preparation: Multiple volume options for different sample sizes
Technical Support & Quality Assurance
Dimensional Accuracy
All crucibles manufactured to ±0.05mm tolerance to ensure perfect fit in Netzsch sample holders and furnaces.
Material Purity
High-purity materials (>99.5% Al₂O₃, 99.9% Pt) to minimize sample contamination and ensure accurate thermal measurements.
Thermal Performance
Each batch validated for thermal conductivity and stability to match Netzsch instrument calibration requirements.
Part Number Cross-Reference
Complete compatibility database available for all Netzsch part numbers including GB, NGB, and HTP series consumables.
Frequently Asked Questions
Are these consumables compatible with all Netzsch instrument generations?
Yes, our consumables are designed to be compatible with both current and legacy Netzsch instruments including F1, F3, and F5 generation systems.
How do I identify the correct crucible for my Netzsch instrument?
Check your instrument manual for the recommended part number (GB, NGB, or HTP series), or contact our technical support team with your instrument model for guidance.
What's the difference between alumina and platinum crucibles?
Alumina offers excellent chemical resistance and high-temperature capability at lower cost. Platinum provides superior inertness for trace analysis and research applications requiring contamination-free results.
*All Netzsch part numbers and instrument models mentioned are for compatibility reference only. We are an independent supplier and not affiliated with Netzsch. All trademarks belong to their respective owners.