Skip to content
Free shipping all over the store
Free shipping all over the store

3.4ml Netzsch Alumina Crucibles TGA Sample Carrier GB445213 For Netzsch DSC crucibles | NEXACULE

Original price $0.00 - Original price $0.00
Original price $0.00
$95.00
$95.00 - $684.00
Current price $95.00

3.4ml Netzsch Alumina Crucibles for TGA Analysis - GB445213

Product Overview

Professional-grade 3.4ml alumina ceramic crucibles designed specifically for Netzsch STA 449 F1/F3/F5 thermogravimetric analysis (TGA) instruments. These high-purity aluminum oxide crucibles offer exceptional thermal stability and chemical inertness, making them ideal for accurate thermal analysis measurements up to 1700°C.

Key Features & Specifications

  • Volume: 3.4ml capacity for optimal sample size
  • Material: High-purity alumina ceramic (Al₂O₃)
  • Temperature Range: Room temperature to 1600°C operating range
  • Maximum Temperature: 1700°C peak performance
  • Part Number: Netzsch GB445213
  • Design: Open crucible (no lid included)
  • Shape: Standard cylindrical design

Compatible Instruments

These crucibles are specifically engineered for use with:

  • Netzsch STA 449 F1 Jupiter®
  • Netzsch STA 449 F3 Jupiter®
  • Netzsch STA 449 F5 Jupiter®
  • Netzsch STA 449 F3 Nevio

Understanding TGA (Thermogravimetric Analysis)

Thermogravimetric Analysis (TGA) is a thermal analysis technique that measures the mass change of a sample as a function of temperature or time. These alumina crucibles provide an inert environment for accurate mass measurements during thermal decomposition, oxidation, and other thermal processes.

Why Alumina Crucibles for TGA?

  • Chemical Inertness: Alumina does not react with most samples
  • High Temperature Stability: Maintains integrity at extreme temperatures
  • Low Thermal Expansion: Minimizes measurement errors
  • Excellent Thermal Conductivity: Ensures uniform sample heating

Available Size Options

Volume Part Number Application
3.4ml A-NE-25 equivalent to Netzsch GB445213 GB445213 Standard TGA analysis
4.2ml A-NA-088-02 Larger sample volumes
5ml A-NA-088-01 equivalent to NGB809163  Maximum capacity

Applications

  • Material Characterization: Thermal stability studies
  • Decomposition Analysis: Reaction kinetics research
  • Purity Assessment: Volatile content determination
  • Quality Control: Production monitoring
  • Research & Development: Material development

Technical Advantages

Superior Material Properties

  • 99.7% alumina purity for minimal interference
  • Low porosity design prevents sample contamination
  • Smooth interior surface for easy cleaning
  • Consistent wall thickness for uniform heating

Usage Guidelines

Sample Preparation

For optimal results, ensure samples are properly prepared and do not exceed the crucible's recommended fill level (typically 2/3 capacity).

Cleaning & Maintenance

  • Clean crucibles before first use
  • Use appropriate solvents for sample residue removal
  • Inspect for cracks or damage before each use
  • Store in clean, dry environment

Lid Options

Important Note: This crucible does not include a lid. If your analysis requires a covered environment, please add the appropriate lid to your cart separately. Contact our technical team for lid compatibility information.

Quality Assurance

  • Manufactured to exact OEM specifications
  • Each batch undergoes quality testing
  • Dimensional accuracy guaranteed
  • Material purity certified

Frequently Asked Questions

Q: What's the difference between TGA and DSC crucibles?

A: TGA crucibles are typically open and designed for mass change measurements, while DSC crucibles often have lids and focus on heat flow measurements. This crucible is optimized for TGA applications.

Q: Can I use these crucibles for other thermal analysis techniques?

A: While designed for TGA, these crucibles can be used for other high-temperature applications, but always verify compatibility with your specific instrument and analysis requirements.

Q: How many times can I reuse these crucibles?

A: With proper care and cleaning, these crucibles can be reused many times. Replace when you notice damage, contamination, or dimensional changes.

Why Choose NEXACULE?

  • Fast delivery (1-7 working days stock time)
  • Competitive pricing for laboratory budgets
  • Expert technical support available
  • Quality guarantee on all products
  • Wide range of compatible accessories

 

Type Sample pan /crucible with lid
Suitable for

Netzsch   DSC 204 F1 Phoenix®, DSC 200 F3 Maia®,

DSC 3500 Sirius and DSC 214 Polyma,

 TG 209 F1 Libra® and TG 209 F3 Tarsus,

STA 449 F1/F3 Jupiter® and DSC 404 F1/F3 Pegasus,

DSC 404 F1/F3 Pegasus, STA 449 F1/F3 Jupiter

Part NO OEM same size as NGB801556  /GB399860  Pt 99.95%
Volume

190μl  

Lid  With
Material PT/Platinum 99.95%
Stocking time

1-7 working days

Import duties or taxes are not included in the item price or shipping charges. These charges are the buyer's responsibility.

Brand NEXACULE
Original MADE IN CHINA

 

TGA vs DSC: Understanding the Difference

Technique Measurement Crucible Design Applications
TGA Mass change Open crucibles Decomposition, volatilization
DSC Heat flow Covered crucibles Phase transitions, reactions

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare