PerkinElmer Sample Pans for DSC and TGA Testing - Ensuring Accurate Results and Preventing Common Issues

How to Resolve Common Issues with PerkinElmer Sample Pans in DSC and TGA Tests

Are you facing issues with PerkinElmer sample pans in your DSC and TGA tests? These common problems can be easily solved with the right approach and attention to detail.

Many researchers and lab technicians encounter various issues when using PerkinElmer sample pans during Differential Scanning Calorimetry (DSC) and Thermogravimetric Analysis (TGA) tests. These issues, like contamination, poor data accuracy, and inconsistent results, can significantly impact your test outcomes. However, with some straightforward solutions, you can easily prevent these problems and ensure more reliable results.

By focusing on the right materials, proper calibration, and avoiding cross-contamination, you can resolve these common problems and improve the accuracy of your data.


Understanding and addressing these issues can save time, reduce errors, and help ensure that your experiments are successful and yield consistent results. Let’s dive into the specifics of each issue and how you can fix them.

How to Avoid Sample Contamination with PerkinElmer DSC and TGA Sample Pans

Contamination is one of the most common issues in thermal analysis. It can alter the composition of the sample and skew results.

To avoid contamination, it's essential to select a sample pan that offers strong chemical resistance, preventing unwanted reactions with the sample. Also, always clean the pans thoroughly between uses to avoid any cross-contamination between different materials.

Dive Deeper

When working with sample pans, it’s crucial to pay attention to the materials they’re made of, as some are more prone to contamination than others. For instance, ceramic pans are generally more resistant to chemical reactions compared to aluminum ones. In addition, ensuring that all surfaces are free of contaminants can prevent interference with measurements. One effective practice is using dedicated pans for specific types of materials to eliminate the risk of cross-contamination.

Material Resistance to Contamination Best Use
Aluminum Moderate Standard applications where chemical resistance is not a critical factor
Ceramic High Tests involving chemically reactive materials
Platinum Very High High-temperature applications requiring minimal contamination

Solving the Problem of Poor Data Accuracy in DSC and TGA with PerkinElmer Sample Pans

Poor data accuracy is another common issue that often arises during thermal analysis. This can occur due to a variety of factors, such as incorrect sample pan material or improper calibration.

To solve this problem, make sure that you’re using the appropriate material for your sample pan. The material’s thermal conductivity, for example, can have a significant impact on the heat transfer and thus on the data’s accuracy. Regular calibration of the equipment is also essential to ensure the accuracy of the measurements.

Dive Deeper

Inaccurate results can arise when the sample pan expands or contracts at different rates than the sample itself, leading to distorted measurements. For example, aluminum pans have a higher coefficient of thermal expansion compared to other materials like platinum. By selecting the right material based on the specific temperature ranges and test conditions of your experiment, you can improve the accuracy of your data. Additionally, always perform regular maintenance and calibration of your equipment to ensure optimal performance and consistency.

Sample Pan Material Coefficient of Thermal Expansion Impact on Accuracy
Aluminum Higher May cause inaccuracies in high-temperature tests due to expansion
Platinum Lower Better accuracy in high-temperature tests due to minimal expansion
Ceramic Very Low Ideal for precision testing and reducing measurement distortion

Why You Might Be Experiencing Inconsistent Results and How to Fix It with the Right Sample Pan

Inconsistent results can often be traced back to using the wrong sample pan or one that is improperly maintained. Variations in material, size, or condition of the pan can all lead to inconsistent readings during DSC and TGA tests.

To fix this, ensure that you are using a sample pan that is appropriate for your specific test parameters. Ensure the pan’s size matches the recommended dimensions for your equipment and experiment. If the pan is deformed or damaged, replace it immediately to prevent inconsistent results.

Dive Deeper

Inconsistent results are often caused by mismatched sample pan sizes or materials. For example, using a pan that is too large or too small for the sample can lead to uneven heating or inaccurate readings. Additionally, damaged or deformed pans can also cause issues, as they may not heat uniformly, which can lead to unreliable data. To avoid this, always use the recommended pan size and material for your tests, and inspect your pans regularly for any signs of wear or deformation.

Issue Potential Cause Solution
Inconsistent Results Incorrect sample pan size Ensure pan size matches test requirements
Data Skewing Deformation or damage to the pan Replace damaged pans immediately
Temperature Variation Wrong material or poor heat conductivity Select the right material for the sample and temperature range

What Causes Sample Pan Deformation and How to Prevent It in PerkinElmer Equipment

Sample pan deformation is another common issue in thermal analysis. This typically occurs at high temperatures and can lead to inaccurate measurements and data inconsistencies.

To prevent sample pan deformation, select a pan material with a low coefficient of thermal expansion, such as platinum or ceramic. Additionally, ensure that your equipment is properly calibrated to minimize stress on the sample pan during testing.

Dive Deeper

Deformation occurs when the sample pan expands due to heat but at a different rate than the sample itself. This can cause the pan to warp or distort, leading to inaccurate results. To prevent deformation, always choose a pan material that is suitable for your specific temperature range and sample type. Additionally, using a pan that fits properly in the equipment is essential to prevent excessive stress during testing.

Material Deformation Resistance Ideal Temperature Range
Aluminum Moderate Up to 600°C
Platinum High Up to 1500°C
Ceramic Very High Up to 1600°C

Conclusion: By carefully selecting the right sample pan material, maintaining proper calibration, and taking care of the pan’s condition, you can avoid common issues like contamination, data inaccuracy, and deformation. These steps will help you achieve more reliable results in your DSC and TGA tests.

Previous article How Aluminum DSC Sample Pans Solve Common Issues in Thermal Analysis

Leave a comment

Comments must be approved before appearing

* Required fields

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare